Operating instructions AG 35
AG35 v01gb
Page 7
4
Installation
The unit may be installed and put into operation by trained electricians only. The above
mentioned person must have read the operating instructions and must follow the instructions,
notes and safety advice.
4.1
Important installation instructions
The charging electrodes connected to the charging generator carry high voltage during
operation. Any contact may lead to injury and consequential accidents.
The operator must
provide protective equipment against direct contact when installing the charging
electrodes!
The operation of the charging generator is not affected by the position in which it is installed.
However, we recommend installing the unit so that the high voltage terminal points downwards
(to protect it from humidity, oil and dirt).
Do not place the charging generator on a surface generating or radiating heat. Avoid installation
positions exposed to direct sunlight.
4.2
Setting up, connecting
1.
Before connecting always check that the unit is suitable for the local mains voltage (the
voltage is indicated on the name plate). The unit will be destroyed if used with wrong mains
voltage.
2.
Attach unit at the desired location using the enclosed retaining plates.
3.
Ensure that the charging generator is switched off (mains switch).
4.
Make the cable connections between the charging electrodes and the high voltage
connection socket.
5.
Connect the PE conductor (green-yellow) with the protective earth of the mains. Connecting
the PE conductor via parts of a machine body is insufficient.
6.
Connect the charging generator to the mains.
7.
Put unit into operation.
Please note in general:
Only plug in/unplug coaxial connector
when the unit is switched off!