8 Technical data
24
8.4
Connected lengths
Unit type
Permissible
connected
length
Maximum
ionizing bar
length Type A
Maximum
ionizing bar
length Type B
Discharging
power pack
18 m
18 m
6 m
Ionizing bar
Type A
EI RN, EI RNE, EI RA, EI RAE, EI RNOF, EI RAOF,
EI HRN, EI HRA, EI HRE, EI HRAE, EI PS, EI PRX,
EI PRV, EI SL, EIW
Type B
EI VS, EI VSE, EI VSA, EI VSAE, EI VC, EI VCA,
EI VCE, EI VCAE, EI VSOF, EI VSAOF
Ionizing bar Type A:
The maximum cable length (KL) is the permissible connected length
(AL) minus the connected ionizing bar length (SL).
KL = AL – SL
Ionizing bar Type B:
The maximum cable length (KL) is the permissible connected length
(AL) minus 3 x the connected ionizing bar length (SL).
KL = AL – (3*SL)