HAUBER-Elektronik GmbH
24
18
Coding HE250
Is your desired configuration not listed? Please contact us and we can offer
you a solution for your specific needs.
HE250. 00. 16. 01. 00. 00. 000
HE series
250 = Monitoring SIL2
4-20 mA ~ mm/s rms + free limit values
4-20 mA bearing status parameter
ATEX / IECEx / EACEx
00 = no ATEX / IECEx / EACEx
01 = ATEX / IECEx / EACEx (Zone 1 / 21)
02 = ATEX / IECEx / EACEx ( Zone 2 / 22)
Measuring range
8 = 8 mm/s rms
10 = 10 mm/s rms
16 = 16 mm/s rms
20 = 20 mm/s rms
25 = 25 mm/s rms
32 = 32 mm/s rms
50 = 50 mm/s rms
64 = 64 mm/s rms
128 = 128 mm/s rms
Frequency range
00 = 10
– 1000 Hz (standard)
01 = 1
– 1000 Hz
Housing material
00 = 1.4305 (V2A) (standard)
01 = 1.4404 (V4A)
Temperature range
00 = -40°C to 85°C
01 = -35°C to 125°C
02 = -20°C to 125°C
Connection
000 = M12 connector (standard)
020 = 2 m integrated cable
050 = 5 m integrated cable
100 = 10 m integrated cable