SPECIFICATIONS
Note: All specifi cations are subject to change without prior notice!
Please visit www.hattelandtechnology.com for the latest electronic version.
2/2
2/6
Button layout and functions:
1 2 3
Status RGB LED
ID
Visual
Simulates
Description
Requires
Physical Operation
1
Decrease / Brightness Negative -
In Normal Mode Press button and release
2
Power Control, configured as ON / OFF
In Normal Mode
Press and hold down
button at least 3 seconds
3
Increase / Brightness Po
In Normal Mode Press button and release
1
Arrow Left, configured as Navigation Back
or as Hot Key #1
In Menu Mode
2
OSD Menu Access, configured as Show/Hide
In Menu Mode
3
Arrow Right, configured as Navigation Forward
or as Hot Key #2
In Menu Mode
-
-
Performs factory reset of the Remote Control
In OFF Mode
Press buttons and hold at
least 10 seconds
-
-
Switches between Normal and Menu Mode as
default configuration on exiting from OFF mode
In OFF Mode
Press buttons and hold at
least 5 seconds
-
-
Turns on or off Status RGB LED visibility as
default configuration on exiting from OFF mode
In OFF Mode
Press buttons and hold at
least 5 seconds
-
-
Status RGB LED to indicate mode to user and
behaviour for the Remote Control
None
The Remote Controller is designed to simulate the regular 6-button available on the Glass Display Control (GDC™)
as default available on all Series X products via a timer-based configuration explained as "Normal" and "Menu"
mode for the Remote Control, all these 6 buttons can be accessed and simulated at the same time, based on a
user intervention such as On-button-first-press (On Down), press-and-hold or just press-and-release on any of the
physical buttons.
1 2 3
1 3 2
Prior to using the Remote Control, the communication mode RS-485 (4-wire) must be configured and the monitor unit's RS adress must be set to "0". Two ways
are possible, either by OSD or by SCOM.
Only the unit with address '0' allows OSD Menu control over remote controller. The units with other addresses do not
support OSD menu control. Normally, the address of each unit on the same bus, has to be unique.
Series X Generation 1 - HD xxT21 MMD
To get access, first change menu mode:
1: OSD Settings > OSD Mode > Full > (Radio Button) and Enter Key Code “362”
2: Management Settings > Communication > 4-wire RS485/422 > (Radio Button)
3: Management Settings > Communication > Address RS > (Slider Bar)
Series X Generation 2 - HD xxT22 MMD
To get access, first change from "Basic Mode" to "Advanced Mode":
1: OSD Miscellaneous > OSD Mode > Advanced > (Select) and Enter Key Code "362"
2: Management Settings > Communication > 4-wire RS485/422 > (Select)
3: Management Settings > Communication > Address RS > (Slider Bar 0~15)
Series X Generation 1 - HD xxT21 STD
To get access, first change menu mode:
1: OSD Misc > OSD Mode > Full > (Radio Button) and Enter Key Code “362”
2: Management > Communication > 4-wire RS485/422 > (Radio Button)
3: Management > Communication > Address RS > (Slider Bar)
Multi Vision Display / MIL - HD xxT22 MVD / HM xxT22 RMD,HM xxT22 CMD:
To get access, first change from "Basic Mode" to "Advanced Mode":
1: OSD Menu > OSD Mode > Advanced> (Select) and Enter Key Code “362”
2: Communication > 4-wire RS485/422 > (Automatic Action)
3: Communication > Address RS > (Slider Bar)
Via SCOM Command (applicable for all units / product ranges above):
Send Bytes (shown here as HEX, 30= value "0"): 07 FF 4D 43 43 02 24 BB 30 14
Configuration of monitor unit: