background image

41

HEX, ASCII, BIN and Character table

IND100077-122

HEX

DEC

BIN

Character/Symbol Description

0x66

102

01100110

f

Lowercase f

0x67

103

01100111

g

Lowercase g

0x68

104

01101000

h

Lowercase h

0x69

105

01101001

i

Lowercase i

0x6A

106

01101010

j

Lowercase j

0x6B

107

01101011

k

Lowercase k

0x6C

108

01101100

l

Lowercase l

0x6D

109

01101101

m

Lowercase m

0x6E

110

01101110

n

Lowercase n

0x6F

111

01101111

o

Lowercase o

0x70

112

01110000

p

Lowercase p

0x71

113

01110001

q

Lowercase q

0x72

114

01110010

r

Lowercase r

0x73

115

01110011

s

Lowercase s

0x74

116

01110100

t

Lowercase t

0x75

117

01110101

u

Lowercase u

0x76

118

01110110

v

Lowercase v

0x77

119

01110111

w

Lowercase w

0x78

120

01111000

x

Lowercase x

0x79

121

01111001

y

Lowercase y

0x7A

122

01111010

z

Lowercase z

0x7B

123

01111011

{

Opening brace

0x7C

124

01111100

|

Vertical bar

0x7D

125

01111101

}

Closing brace

0x7E

126

01111110

~

Equivalency sign - tilde

0x7F

127

01111111

Delete (no visible character)

0x80

128

10000000

Euro sign

0x81

129

10000001

(no visible character)

0x82

130

10000010

Single low-9 quotation mark

0x83

131

10000011

ƒ

Latin small letter f with hook

0x84

132

10000100

Double low-9 quotation mark

0x85

133

10000101

Horizontal ellipsis

0x86

134

10000110

Dagger

0x87

135

10000111

Double dagger

0x88

136

10001000

ˆ

Modifier letter circumflex accent

0x89

137

10001001

Per mille sign

0x8A

138

10001010

Š

Latin capital letter S with caron

0x8B

139

10001011

Single left-pointing angle quotation

0x8C

140

10001100

Œ

Latin capital ligature OE

0x8D

141

10001101

(no visible character)

0x8E

142

10001110

Ž

Latin captial letter Z with caron

0x8F

143

10001111

(no visible character)

0x90

144

10010000

(no visible character)

0x91

145

10010001

Left single quotation mark

0x92

146

10010010

Right single quotation mark

0x93

147

10010011

Left double quotation mark

0x94

148

10010100

Right double quotation mark

0x95

149

10010101

Bullet

0x96

150

10010110

En dash

0x97

151

10010111

Em dash

0x98

152

10011000

˜

Small tilde

Summary of Contents for HD 12T21 D F Series

Page 1: ...e SCOM TECHNICAL MANUAL Technical Manual SCOM Series X G1 Updated 02 Nov 2021 Doc Id INB100018 4 Rev 20 Created 6542 6784 363 Approved 6644 Applies for Series X Maritime Multi Display Generation 1 G1...

Page 2: ...righted to the respective owners The products may not be copied or duplicated in any way This documentation contains proprietary information that is not to be disclosed to persons outside the user s c...

Page 3: ...zer Control 13 DL Query available ECDIS packages 13 DLN Download ECDIS package table x 15 ETC Elapsed Time Counter Query 16 FHA Feature Header Potentiometer 16 FWV Firmware FW Version Video chipset Cy...

Page 4: ...4 IND100130 46 4 Contents Appendixes 35 Calculating Checksums IDCHK IHCHK 36 HEX ASCII BIN and Character table 39 C Pseudo Ethernet TCP Code example 44 Revision History 45...

Page 5: ...port 10001 IP address for the computer must be on the same subnet as the internal set IP of the unit The local software firewall on computer router or network system must accept communication in out...

Page 6: ...he power ripple may cause radiated emission to fail Use a cable that contains at least 2 wires not 2 single wires Test connection beep with Voltage Meter Wires may be combined if using RS 422 485 COM...

Page 7: ...NPN Transistor Rating 500mA Internal Side External Side Note Requires soldering and assembly It is expected that the technician has experience in electronics soldering and assembling cables and conne...

Page 8: ...is needed or required Every command sent and received are always ended with a 0x00 null byte terminator ATTN Attention ATTN This single byte is used to identify a start of message 3 values are possibl...

Page 9: ...inimum Brightness W 0x49 0x4E 0x56 INV Flip image upside down 12 and 15 inch units only W 0x4C 0x49 0x53 LIS Read Ambient Light Sensor R 0x4D 0x41 0x4E MAN Manufacturer ID Code R 0x50 0x4F 0x54 POT Po...

Page 10: ...ich case there will be no reply DATA Data Field DATA The single byte is the DATA field which shall only be transmitted if LEN is greater than 0 This field depends on the CMD transmitted IDCHK Inverse...

Page 11: ...y Control GDC LED s on the front glass From 0x00 to 0x31 0 100 The brightness value shall be sent as 1 byte in the DATA field A setting of 0x00 shall indicate off A setting of 0x31 shall indicate maxi...

Page 12: ...ATA field in the reply will indicate the current brightness control setting Example If BRT is 100 the user can adjust the brightness from 0 100 If the BRT is set to 60 the visual brightness is set to...

Page 13: ...as example 42 34 it will always be rounded up wards i e 43 packets The DL command does not indicate which memory slot was used to store the ECDIS table so please review the Slot ECDIS condition table...

Page 14: ...ou can issue a DL command with positive response however note that this setting is part of the OSD menu functions and it can be changed manually by users at any time naturally making the response fals...

Page 15: ...d and table nr the first byte in the DATA field represents a hexadecimal word 00 to FF identifying the block of data to be downloaded The second byte in the DATA represents the table nr from 1 x If th...

Page 16: ...rs 99999 Example Command to Query ETC 0x07 0xFF 0x45 0x54 0x43 0x00 0x1D Acknowledge 0 0 0 5 8 combined 00058 or 58 hours 0x06 0xFF 0x45 0x54 0x43 0x05 0x19 0x30 0x30 0x30 0x35 0x38 0x02 The ETC value...

Page 17: ...ge FWV 120306V1 0x06 0xFF 0x46 0x57 0x56 0x08 0xFF 0x30 0x33 0x30 0x36 0x56 0x31 0x4C GMB Glass Display Control GDC Minimum Brightness Sets the minimum value limit for the backlight of the LED s on th...

Page 18: ...ledge LIS value is 0 0 9 9 9 999 0x06 0xFF 0x4C 0x49 0x53 0x05 0x0D 0x30 0x30 0x39 0x39 0x39 0xF4 MAN Manufacturer ID This command is sent to the unit to request Manufacturer ID No data shall be sent...

Page 19: ...attention code The DATA field will indicate the resulting control setting If an invalid data checksum was received and the message was not broadcast and RS 485 the unit will reply with a NAK attentio...

Page 20: ...oftware Version query 0x07 0xFF 0x53 0x57 0x49 0x00 0x06 Acknowledge GEV software query 120801V1_M 0x06 0xFF 0x53 0x57 0x49 0x0A 0xFD 0x31 0x32 0x30 0x38 0x30 0x31 0x56 0x31 0x5F 0x4D 0xA0 SWK Glass D...

Page 21: ...MJDOABA FYI Which translates to HD 17T21 MMC with a configuration added to it by using the letters MJD OABA The meaning of MJD OABA can only be found in the description field of invoice documents and...

Page 22: ...0 1 2 3 4 5 6 7 8 7 LEN 8 LEN 0x07 0xFF 0x4D 0x43 0x43 LEN IHCHK Command ID Data1 Datax IDCHK Command ID Supported Command ID in video scaler Command list Data Defines the data of option numbers inqui...

Page 23: ...available on earlier units MCC Command Syntax and Functionality Details and Values Brightness Control Syntax 07 FF 4D 43 43 03 23 81 xx yy zz Function Examples Example 50 07 FF 4D 43 43 03 23 81 35 30...

Page 24: ...3 02 24 88 xx zz Function Examples Example 1 07 FF 4D 43 43 02 24 88 31 46 Query 07 FF 4D 43 43 02 24 88 3F 38 Reset R 07 FF 4D 43 43 02 24 88 52 25 Reset r 07 FF 4D 43 43 02 24 88 72 05 Where xx 0 to...

Page 25: ...43 43 03 23 91 35 30 09 Query 07 FF 4D 43 43 02 24 91 3F 2F Reset R 07 FF 4D 43 43 02 24 91 52 1C Reset r 07 FF 4D 43 43 02 24 91 72 FC Increase 07 FF 4D 43 43 02 24 91 2B 43 Decrease 07 FF 4D 43 43...

Page 26: ...02 24 99 xx zz Function Examples Example 2 07 FF 4D 43 43 02 24 99 32 34 Query 07 FF 4D 43 43 02 24 99 3F 27 Reset R 07 FF 4D 43 43 02 24 99 52 14 Reset r 07 FF 4D 43 43 02 24 99 72 F4 Where xx 0 to...

Page 27: ...43 43 02 24 A3 52 0A Reset r 07 FF 4D 43 43 02 24 A3 72 EA Increase 07 FF 4D 43 43 02 24 A3 2B 31 Decrease 07 FF 4D 43 43 02 24 A3 2D 2F Where xx 0 to 6 Where yy 0 to F Where zz Calculated Checksum Ma...

Page 28: ...hecksum Max Range 0 0 to 6 4 Default 3 2 Green Level for Selected Color Temperature Syntax 07 FF 4D 43 43 03 23 B5 xx yy zz Function Examples Example 50 07 FF 4D 43 43 03 23 B5 35 30 E5 Query 07 FF 4D...

Page 29: ...v1 v2 v3 2E w1 W2 W3 2E x1 x2 x3 2E y1 y2 y3 zz Function Examples Example fixed IP 192 168 1 35 Send 192 168 001 035 07 FF 4D 43 43 10 16 BC 31 39 32 2E 31 36 38 2E 30 30 31 2E 30 33 35 55 Set Auto IP...

Page 30: ...Available response status 0 Fail 1 Successful Load User Default Syntax 07 FF 4D 43 43 02 24 D8 xx zz Function Examples Example 3 07 FF 4D 43 43 02 24 D8 33 F4 Where xx 1 to 5 Where zz Calculated Check...

Page 31: ...to the original factory default value The factory default value will vary depending on the command and or with customized units Both R 0x52 and r 0x72 can be used to execute the reset command Increas...

Page 32: ...mode RS 485 broadcast command messages after the last byte of the command message is received all units will reply within the time period defined for Te below Further more any gap between these indiv...

Page 33: ...be processed to check for the start of a new command 0x07 ASCII Bell If the header checksum is valid but the first byte of the command message is not 0x07 as specified the unit may wait until after th...

Page 34: ...34 This page left intentionally blank...

Page 35: ...35 Appendixes...

Page 36: ...l to binary We place in the table below marked in green 1 or 0 for the highest available decimal number in that cell and subtract until we reach 0 So in the case of 55 it is 55 32 16 4 2 1 0 1 or 0 0...

Page 37: ...e 0001 1101 inverted is by using explanations on previous page 1110 0010 Convert 1110 0010 to decimal is 226 or as HEX 0xE2 Attention Address CMD CMD CMD Length IHCHK 55 230 226 IDCHK with three data...

Page 38: ...or as HEX 0x42 CMD 2 field 82 or as HEX 0x52 CMD 3 field 73 or as HEX 0x49 Length field 1 or as HEX 0x01 Length of 1 indicates only 1 byte 55 is present in DATA field Add all the fields together 7 25...

Page 39: ...oft XOFF 0x14 20 00010100 DC4 Device Control 4 0x15 21 00010101 NAK Negative Acknowledgement 0x16 22 00010110 SYN Synchronous Idle 0x17 23 00010111 ETB End of Transmit Block 0x18 24 00011000 CAN Cance...

Page 40: ...1001000 H Uppercase H 0x49 73 01001001 I Uppercase I 0x4A 74 01001010 J Uppercase J 0x4B 75 01001011 K Uppercase K 0x4C 76 01001100 L Uppercase L 0x4D 77 01001101 M Uppercase M 0x4E 78 01001110 N Uppe...

Page 41: ...11110 Equivalency sign tilde 0x7F 127 01111111 Delete no visible character 0x80 128 10000000 Euro sign 0x81 129 10000001 no visible character 0x82 130 10000010 Single low 9 quotation mark 0x83 131 100...

Page 42: ...e sign 0xB1 177 10110001 Plus or minus sign 0xB2 178 10110010 Superscript two squared 0xB3 179 10110011 Superscript three cubed 0xB4 180 10110100 Acute accent spacing acute 0xB5 181 10110101 Micro sig...

Page 43: ...th circumflex 0xE3 227 11100011 Latin small letter a with tilde 0xE4 228 11100100 Latin small letter a with diaeresis 0xE5 229 11100101 Latin small letter a with ring above 0xE6 230 11100110 Latin sma...

Page 44: ...sion of the SCOM package byte byteMessage byte commessage Message ToArray typeof byte Display IP adresse IPAddress displayAddr IPAddress Parse DisplayIPAddress Int32 port 10001 constant Connecting tcp...

Page 45: ...to using MCC command page 14 15 07 ME WJ SE 30 Oct 2014 Removed Note DC power only notice for Power Down Up command Works with AC DC page 26 08 MS SE 11 Dec 2014 Added note for XON XOFF flow control...

Page 46: ...vision History IND100332 7 20 YR WJ VM SE 02 Nov 2021 Removed all references to STD and MMC models this manual now only covers specifically MMD Revised Calculating Checksums IDCHK IHCHK chapter page 3...

Page 47: ...47 Revision History IND100332 7...

Page 48: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...

Reviews: