1.  POWER REQUIREMENTS 

 

NOTE:  The fuse size listed is the recommended size for a dedicated inline fuse.   
If using a fused power source, verify that it is capable of handling the indicated amperage in addition to any other existing loads! 

WARNING:  DO NOT OPERATE THIS COMPRESSOR IF THE SYSTEM VOLTAGE IS BELOW 12V! 

Power Source 

Power Source Connection 

Fuse Size 

12-14V DC 

Alligator Clamp to Yellow Connector 

40A 

115V AC Outlet 

Wall Plug to Black Connector 

7.5A 

230V AC Outlet 

Wall Plug to Black Connector 

4A 

Additional Information 

Flow Rate 

0.25 CFM (0.007 m³/min) 

 

2.   PARTS OF YOUR COMPRESSOR 

Summary of Contents for TactAir Volt

Page 1: ...Hatsan TactAir Volt Dual Power Portable Compressor Operation Manual REV1 3 2020...

Page 2: ...2...

Page 3: ...thers 7 Disassembly of this compressor can result in leaks damage and will void your warranty 8 Do not transport or place this compressor into a storage location while it is pressurized or is hot afte...

Page 4: ...or any reason Use caution when purging air from the system Loosen the vent screw slowly The escaping air can cause damage Noise from purging may be loud especially if you are in a small space Hearing...

Page 5: ...e in addition to any other existing loads WARNING DO NOT OPERATE THIS COMPRESSOR IF THE SYSTEM VOLTAGE IS BELOW 12V Power Source Power Source Connection Fuse Size 12 14V DC Alligator Clamp to Yellow C...

Page 6: ...illuminate and show system voltage Operating voltage is 12 14V 4 FIRST RUN LEAK TEST Follow the steps below prior to using the compressor to fill any reservoir before use after storage or any time you...

Page 7: ...ipped to verify the pressure does not exceed that of the operating pressure of the device 7 The compressor will stop running once it has reached the set pressure and display a message confirming that...

Page 8: ...to allow the compressor to cool before handling or moving after it has been used Leak Checks Perform a System Leak Test every 30 hours of runtime or every six months whichever occurs first o Additiona...

Page 9: ...nnected Insert test plug into fill whip or connect whip to reservoir System takes a long time to fill or build pressure Bleed valve is open or partially open Close bleed valve by turning the screw clo...

Page 10: ...r Return shipping of the repaired or replaced product back to the consumer What Is NOT Covered Repairs required due to abuse misuse neglect or failure to perform proper maintenance Damages resulting f...