![Hatco UGA-18 Installation And Operating Manual Download Page 14](http://html.mh-extra.com/html/hatco/uga-18/uga-18_installation-and-operating-manual_2106929014.webp)
INSTALLATION
12
Form No. UGAM-0908
General
Use the information in this section to prepare for
installation of the strip heater. Make sure to locate the
specific information for the model of strip heater and
type of installation.
FIRE HAZARD: Do not install Ultra-Glo
®
strip
heaters above or around combustible surfaces.
Discoloration or combustion could occur.
Ultra-Glo strip heaters must be installed in non-
combustible surroundings only.
To ensure safe and proper operation, refer to the
“Minimum Clearance Requirements” listed in
the INSTALLATION section of this manual.
Heat damage to countertop material such as
Corian
®
and similar products (other than
stainless steel) is not covered under the Hatco
warranty. Contact the manufacturer of the base
material for temperature limits and application
information before installing the unit.
To prevent unit failure from excessive heat, do
not add a decorative soffit to hide a pass-
through mounted strip heater.
NOTE: Contact the countertop manufacturer of the
base material for application information
and surface temperature limits before
installing the unit.
1. Remove the unit from the shipping carton and
remove all packing materials.
2. Remove the information packet.
NOTE: To prevent delay in obtaining warranty
coverage, fill out and mail in the warranty
card to Hatco.
NOTE: If unit is equipped with optional equipment,
see the
OPTIONS
section near the back of
this manual.
NOTICE
CAUTION
WARNING
Dual Mounting
When mounting units side-by-side, a space not less
than 3″ (76 mm) must be maintained between units.
Dual units ordered from the factory are shipped with
a pre-assembled 3″ (76 mm) or 6″ (152 mm) spacer.
Installation of two or more separate units with
less than 3″ (76 mm) between housings may
result in premature failure of component parts.
Failure to provide proper spacing may result in
heat damage to electrical components.
Under Shelf Mounting
When mounting a unit under a shelf, use adjustable
angle brackets to assure proper spacing. Remote
control enclosures are recommended to keep
switches out of the heat zone and prevent premature
failure.
Pass-Through
If pass-through area is 12″ to 16″ (305 to 406 mm)
deep, a single unit can be used. For a 20″ to 24″ (508
to 610 mm) deep pass-through area, a dual unit is
recommended. Installation of multiple units must
have a minimum spacing of 3″ (76 mm) between
heaters.
Over Steam Table
When mounting over a steam table, a remote control
enclosure must be installed.
NOTICE
All manuals and user guides at all-guides.com