SPECIFICATIONS
Electrical Rating Chart
Plug Configuration
Units are supplied from the factory with an electrical cord and
plug installed. Plugs are supplied according to the application.
WARNING
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: The specification label is located on the bottom of the
unit. See label for serial number and verification of unit
electrical information.
NEMA 5-15P
Plug Configuration
NOTE: Receptacle not supplied by Hatco. All units must be
connected to a dedicated 15 A circuit.
Dimensions
A
C
B
E
D
Front View
Side View
Top View
Model
Voltage
Watts
Amps
Plug Configuration
Unit Weight
IRNG-PC1-14
120
1440
12
NEMA 5-15P
14 lbs. (6 kg)
IRNG-PC1-18
120
1800
15
NEMA 5-15P
14 lbs. (6 kg)
Model
Width (A)
Depth (B)
Height (C)
Footprint Width (D)
Footprint Depth (E)
IRNG-PC1-14
13ʺ (330 mm)
17ʺ (431 mm)
3-7/16ʺ (86 mm)
12ʺ (304 mm)
13-3/8ʺ (339 mm)
IRNG-PC1-18
13ʺ (330 mm)
17ʺ (431 mm)
3-7/16ʺ (86 mm)
12ʺ (304 mm)
13-3/8ʺ (339 mm)