Form No. RHWm-1215
7
INSTALLATION
English
6. Install the control box in the control box cutout:
a. Remove the four screws that secure the front cover to
the control box. Remove the front cover and pass it
through the cutout to the front of the installation surface.
b. Pass one of the mounting flanges on the control box
housing through the cutout. Tilt and slide the other
flange through the cutout.
c. align the holes on the mounting flanges with the screw
holes in the installation surface, and secure the control
box housing to the surface using four screws (not
supplied).
d. Install the front cover on the control box using the four
front cover screws.
Installing the Remote mounted Control Box
7 Plug the power cord into a properly grounded electrical
outlet of the correct voltage, size, and plug configuration.
See the SPECIFICaTIONS section for details.
HEATED
WELL
HATC
O CO
RPOR
ATION
MILW
AUKE
E, WI U
.S.A.
www.h
atcoco
rp.com
Front
Cover
Control Box
Housing
Mounting Flange
Front Cover
Screws
3. Guide the control box with the front cover removed and the
electrical cords through the countertop cutout, and then
lower the unit into the cutout.
Installing the Unit
4. assemble the L-brackets to the
underside of the unit.
5. Tighten the L-bracket screws until
the top flange lies flat on the
countertop.
Do not use excessive force when
tightening mounting screws on
built-in units. This may damage unit
and/or countertop.
HEATED
WELL
HATC
O CO
RPOR
ATION
MILW
AUKE
E, WI U
.S.A.
www.h
atcoco
rp.com
Countertop
Cutout
Control Box
Cutout
Screw
Control
Box
Front
Cover
Screw
Screw
Top Flange
Countertop
L Bracket
L Bracket
NOTICE