Installing an Under Shelf Mounted
Control Box
Use the following procedure to install the under shelf mounted
control box.
NOTICE
Install remote-mounted control box outside of areas
subject to temperatures above 40°C (104°F). Excessive
temperatures will cause controls to overheat, malfunction,
and fail.
IMPORTANT NOTE:
Remote-mounted control boxes and control switches must
be installed in a cool, dry location as far away from any
heat zone as possible. Do not mount control boxes directly
on, under, or above unit. Do not mount control boxes in
direct contact with any heated surface or near any steam
generating equipment.
1. Drill the appropriate holes in the surface where the control
box will be installed, if necessary. Refer to the "Control
Box Screw Hole Dimensions" illustration for screw hole
dimensions.
42 mm
(1-5/8")
220 mm
(8-11/16")
Top View
Control Box Screw Hole Dimensions
NOTE: Make sure the control box installation location provides
enough space for the depth of the control box and
electrical connections.
2. Route the element wire leads and the LED wire leads
from the unit to the control box and make the electrical
connections.
3. Plug the power cord into a properly grounded electrical
receptacle of the correct voltage, size, and plug
configuration. See the SPECIFICATIONS section for
details.
Power Cord
Power
to Unit
Access
Cover
Under Shelf Mounted Control Box Electrical Connections
4. Position the control box into position under the horizontal
surface. Make sure that none of the electrical wires are
pinched or stressed.
5. Fasten the control box to the horizontal surface using four
screws (not supplied).
Screw
Control
Box
Shelf
Installing the Under Shelf Mounted Control Box
INSTALLATION