HEAT PATTERNS
PRE-FOCUSED:
The Hatco Glo-Ray
®
radiating reflector directs infrared heat from the element
to the holding area recommended. Mounting heights vary depending on the type of heating element.
MOUNTING ARRANGEMENTS
BRACKETS:
Standard hanger tabs are provided for undershelf, over shelf or chain installation.
An optional angle bracket allows vertical adjustment that fits 6" or 9" (152 or 229 mm) housings.
STANDS:
A variety of optional stands are available for permanent and portable installation.
Available for both standard and high
wattage elements.
CAUTION:
Do not install Glo-Ray
®
warmers less than
10" (635 mm)
ABOVE NON-METALLIC SURFACE
when using
standard wattage elements or
13" (330 mm) ABOVE NON-
METALLIC SURFACE
with high wattage elements.
Dual warmers must be at least
30" (762 mm) ABOVE
NON-METALLIC SURFACES.
DO NOT INSTALL CLOSER THAN 3" (76 mm)
BETWEEN WARMERS.
18"-24"
(457-610 mm)
10"-16"
(254-406 mm)
Optional slant reflectors are available to direct
the heat pattern left or right.