background image

Formulaire n° GR3SDSCTM-1119

15

Français

Modéle

Circuit

Tension

Intensité

Amps

Configuration de 

Fiches

Poids 

d’embarquement

GR3SDS-27DCT

---

120

1340

11.2

NEMA 5-15P

70 kg (155 lbs.)

GR3SDS-27TCT

1

120

980

8.2

NEMA 5-15P

86 kg (190 lbs.)

2

120

1115

9.3

NEMA 5-15P

---

120/208-240

2095

17.5

NEMA L14-20P

GR3SDS-33DCT

---

120

1747

14.6

NEMA 5-15P

*

79 kg (175 lbs.)

GR3SDS-33TCT

1

120

1293

10.8

NEMA 5-15P

98 kg (215 lbs.)

2

120

1555

13.0

NEMA 5-15P

---

120/208-240

2723

11.9

NEMA L14-20P

GR3SDS-39DCT

1

120

1530

12.8

NEMA 5-15P

84 kg (186 lbs.)

2

120

600

5.0

NEMA 5-15P

---

120/208–240

2130

12.8

NEMA L14-20P

GR3SDS-39TCT 

1

120

1555

13.0

NEMA 5-15P

104 kg (230 lbs.)

2

120

1755

14.6

NEMA 5-15P

---

120/208–240

3310

14.6

NEMA L14-20P

 

CARACTÉRISTIQUES TECHNIQUES

Tableau des valeurs nominales électriques

Configuration des fiches

Les appareils sont fournis par l’usine avec un ou deux jeux de 

cordons et de prises électriques pré-installés.

AVERTISSEMENT

DANGER DE DÉCHARGE ÉLECTRIQUE: Brancher 

l’appareil sur une prise électriques avec terre de tension, 

de format et de configuration des broches corrects. Si 

la fiche et la prise électriques ne se correspondent pas, 

s’adresser à un électricien qualifié pour déterminer et 

installer une prise électrique de format et de tension 

corrects.

NOTA:  Les prise électriques ne sont pas fournies par Hatco.

NEMA 5-15P

NEMA L14-20P

NEMA 5-20P

Configuration des fiches

NOTA: Étiquette de spécifications sur le dos de l’appareil. 

Consultez l’étiquette pour connaître le numéro de série 

et vérifier les caractéristiques électriques de  l’appareil.

NEMA 5-20P pour le Canada.

NOTA:  Les appareils à deux circuits sont équipés de deux jeux de cordons d’alimentation et de prises, nécessitant deux circuits 

électriques 120 V et 15 A indépendants.

NOTA:  Le poids d’embarquement comprend l’emballage.

Summary of Contents for Glo-Ray GR3SDS-27DCT

Page 1: ...imiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localizaci n segura para la referencia f...

Page 2: ...imum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Spe...

Page 3: ...oper voltage and size electrical receptacle Turn OFF power switches unplug power cord s and allow unit to cool before performing any cleaning adjustments or maintenance This unit has one or two power...

Page 4: ...ets The warmer features two heat sources The first is the thermostatically controlled hardcoated base shelf and canopy The second heat source consists of the glass shelf shelves that conducts heat to...

Page 5: ...NEMA L14 20P SPECIFICATIONS Electrical Rating Chart Plug Configurations Units are supplied from the factory with one or two electrical cords and plugs installed WARNING ELECTRIC SHOCK HAZARD Plug unit...

Page 6: ...m 30 3 4 780 mm 24 608 mm 5 3 4 147 mm GR3SDS 33TCT 33 3 16 843 mm 27 15 16 710 mm 34 9 16 877 mm 30 3 4 780 mm 24 608 mm 5 3 4 147 mm GR3SDS 39DCT 39 3 16 995 mm 27 1 2 698 mm 26 1 2 673 mm 36 5 8 93...

Page 7: ...ly lay unit on its side and remove the four rubber shipping feet if installed This step requires two people NOTE Place a piece of cardboard between the unit and the floor to prevent marring the unit f...

Page 8: ...sponds to the control Turning a Heat Control knob clockwise will decrease the temperature setting Turning a Heat Control knob counterclockwise will increase the temperature setting Turning a Shelf Hea...

Page 9: ...that will allow them to operate safely in Hatco equipment Daily Cleaning To preserve the finish of the unit as well as maintain performance it is recommended that the unit be cleaned daily NOTICE Use...

Page 10: ...ng Base glass shelf and or canopy heat too hot Corresponding Heat Control Knob s set too high Adjust the appropriate Heat Control Knob s to a lower setting Heat Control s not working properly Contact...

Page 11: ...PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescen...

Page 12: ...le une apparence attractive et des performances optimales Chaque appareil est soigneusement inspect et test avant exp dition Informations Importantes pour le Propri taire 12 Introduction 12 Consignes...

Page 13: ...travail ou install s au dessus de ce dernier Si l appareil ne peut pas tre fix sur l emplacement d utilisation des pieds de 64 mm 2 1 2 sont fournis pour permettre le nettoyage en dessous de l quipem...

Page 14: ...N DU MOD LE G R 3 S D S xx x C T Glo Ray tag re chauffante en verre Vitrine pour sandwichs Mod le inclin Largeur totale pouces D Rayonnage double T Rayonnage triple Auvent incurv DESCRIPTION DU MOD LE...

Page 15: ...fiches Les appareils sont fournis par l usine avec un ou deux jeux de cordons et de prises lectriques pr install s AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise lectriqu...

Page 16: ...30 3 4 608 mm 24 147 mm 5 3 4 GR3SDS 33TCT 843 mm 33 3 16 710 mm 27 15 16 877 mm 34 9 16 780 mm 30 3 4 608 mm 24 147 mm 5 3 4 GR3SDS 39DCT 995 mm 39 3 16 698 mm 27 1 2 673 mm 26 1 2 930 mm 36 5 8 604...

Page 17: ...es pieds de 64 mm 2 1 2 sur le fond de l appareil a Retirer le butoir porte tiquettes sur chaque rayonnage b Coucher soigneusement l appareil sur le c t Cette tape n cessite deux personnes NOTA Placer...

Page 18: ...ic ne de la source de chaleur sous le bouton indique quelle plaque correspond ce bouton Si vous tournez le bouton de contr le de la chaleur dans le sens des aiguilles d une montre cela augmentera le r...

Page 19: ...de Contr le de la Base Chauffante Interrupteur de de l clairage I O marche arr t Interrupteurs d alimentation I O marche arr t Boutons de commande de la temp rature des plaques Bouton de commande de...

Page 20: ...danger dans la mat riel Hatco Nettoyage quotidien Afin de pr server la finition de l unit et de conserver son efficacit il est recommand de nettoyer l unit quotidiennement AVIS Utilisez uniquement de...

Page 21: ...chauffage et ou les rayonnages chauffants ne fonctionnent pas Le socle le rayonnage et ou l auvent chauffent trop Le s bouton s de contr le de la chaleur correspondant s est sont r gl s sur une posit...

Page 22: ...REVETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clair...

Page 23: ...Form No GR3SDSCTM 1119 23 English NOTES NOTA...

Page 24: ...rvice St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repa...

Reviews: