  6. Install  the  included  4″  (102  mm)  legs  (two  people  are

required for this step). 

       a. Tape the rear glass doors together to prevent them from

opening while tipping.

       b. Carefully tip the unit onto its side and rest it on top of

cardboard on a flat surface.

       c. at each corner, thread a 4″ (102 mm) leg into the bottom

of the unit. Hand-tighten until almost snug. Do not over-

tighten.

       d. Return the unit to the upright position.
       e. Remove the tape from the doors.

NOTE: The feet on the 4″ (102 mm) legs are adjustable for

leveling the unit. Use a 9/16″ (14 mm) open-end wrench

to make leveling adjustments once the unit is placed in

its final position.

Vent Panel

Stone Base

Glass Top Shelf

Side

Air Deflector

Front

Air Deflector

Locating

Peg

4″

(102 mm)

Legs

Perforated 

Stainless Steel

Top Shelf

Sign Holder

removed

for clarity. 

Leg Installation

  7. Reinstall the stone base shelf. 
       a. Remove all tape and protective packaging from the shelf.
       b. align the two holes on the back edge of the shelf with

the locating pegs on the base.

       c. Carefully lower the shelf into position.

  8. Reinstall the front air deflector along the front edge of the

base. Long slots on air deflector should face to the front.

  9. Install the side air deflectors.

         • The side deflectors rest between two screw heads on

each side of the base, directly in front of the side air

vents. The flat edge of the deflector should be positioned

against the glass side panel.

10. Install the top shelf.

         • If the unit is configured with a glass top shelf, install the

vent panel along the front edge of the top shelf frame.

Then, install the glass shelf.

         • If the unit is configured with a perforated stainless steel

top shelf, install the shelf directly into the top shelf frame.

Perforated stainless steel top shelves are designed to

allow proper air flow without the use of the vent panel.

continued...

Lengthen

Shorten

Adjustable

Foot

4″ Leg

Drain Valve

Summary of Contents for FLAV-R-SAVOR FSCD Series

Page 1: ...s que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual conti...

Page 2: ...e at www hatcocorp com 24 Hour 7 Day Parts and Service Assistance available in the United States and Canada by calling 800 558 0607 INTRODUCTION Hatco Flav R Savor Convected Display Cabinets are desig...

Page 3: ...ectrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical r...

Page 4: ...ning clips They come standard with a black powdercoated finish and are available in several other Designer colors all models feature a digital temperature controller a lighted PoWER oN oFF I o switch...

Page 5: ...are supplied from the factory with an electrical cord and plug installed plugs are supplied according to the application ELECTRIC SHOCK HAzARD plug unit into a properly grounded electrical receptacle...

Page 6: ...ge complete online warranty registration See the ImPoRTaNT oWNER INFoRmaTIoN section for details 4 Place the unit in the desired location Locate the unit in an area where the ambient air temperature i...

Page 7: ...Installation 7 Reinstall the stone base shelf a Remove all tape and protective packaging from the shelf b align the two holes on the back edge of the shelf with the locating pegs on the base c Careful...

Page 8: ...nel toward the unit until it rests against the upper frame and the glass side panels c Tighten the thumbscrews holding the curved glass retaining clips on each side of the panel Front Sign Holder Hing...

Page 9: ...ts NOTE Unit failure caused by deionized water is not covered by warranty 4 For humidified units fill the water reservoir with clean water To fill the reservoir a Lift up the WaTER FILL cup cover and...

Page 10: ...aBINET TEmPERaTURE display shows the lowest temperature point inside the cabinet not the product temperature Setting the Humidity Level Use the following procedure to set the humidity level on humidif...

Page 11: ...o the Cleaning the Stone Surface information in this section NOTE To correct inconsistent staining and discoloration refer to the Cleaning the Stone Surface information in this section e Wipe dry with...

Page 12: ...usual for daily operation using the procedure in the oPERaTIoN section of this manual Drain Valve Valve handle in closed position Valve handle in open position Replacing Xenon Display Lights The ligh...

Page 13: ...eating elements or heating elements defective Contact authorized Service agent or Hatco for assistance Unit is heating but is not producing humidity inside cabinet Lo H20 flashes on display and unit i...

Page 14: ...ated top shelf pan Risers Pan risers are available to prolong the holding time of moist products Pan Riser Drain Valve Relocation Drain valve relocation is available for humidified units as a factory...

Page 15: ...PURPoSE oR PaTENT oR oTHER INTELLECTUaL PRoPERTY RIGHT INFRINGEmENT Without limiting the generality of the foregoing SUCH WaRRaNTIES Do NoT CoVER Coated incandescent light bulbs fluorescent lights he...

Page 16: ...rechange disponible 7j 7 24h 24 aux tats Unis et au Canada en composant le 800 558 0607 INTRODUCTION Les vitrines convection Flav R Savor de Hatco sont con ues pour conserver des plats pr par s penda...

Page 17: ...ANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adre...

Page 18: ...taille et un de petite taille 1 3 NOTE Les surfaces en pierre sont en pierre artificielle Les appareils qui peuvent tre configur s avec ou sans syst me d humidification sont pourvus d un cordon d alim...

Page 19: ...sont fournies en fonction de l application DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fic...

Page 20: ...pareil l endroit d sir Placez l appareil un endroit o la temp rature ambiante est constante et de 21 C 70 F minimum vitez les endroits susceptibles d activer les mouvements ou les courants d air comme...

Page 21: ...Support d enseigne non montr pour plus de lisibilit Installation des pieds 7 Replacez l tag re inf rieure en pierre a Retirez le ruban et l emballage de protection de l tag re b alignez les deux orif...

Page 22: ...il repose contre la partie sup rieure du cadre et les panneaux lat raux en verre c Serrez les vis de fixation des fermoirs de chaque c t du panneau en verre Support d enseigne frontal Vis de charni r...

Page 23: ...vertes par la garantie 4 Dans les appareils avec syst me d humidification remplir le r servoir avec de l eau propre Pour remplir le r servoir a Soulever le couvercle du godet de remplissage d eau et l...

Page 24: ...mp rature affiche la temp rature la plus basse l int rieur de l armoire et non la temp rature du produit R glage du taux d humidit Suivre la proc dure suivante pour r gler le niveau d humidit sur les...

Page 25: ...re humide non abrasif d Nettoyer et d sinfecter les surfaces en pierre en utilisant un tissu propre et humide et un d sinfectant agr pour les surfaces en contact avec des aliments Si un nettoyage plus...

Page 26: ...mentation et remplir le r servoir comme d habitude pour une utilisation quotidienne en suivant la proc dure de la section moDE D EmPLoI dans ce manuel Robinet de vidange Poign e du robinet en position...

Page 27: ...votre agent de maintenance agr ou Hatco pour assistance L appareil chauffe mais ne produit pas d humidit dans la vitrine Lo H20 clignote et l appareil est rempli d eau Si vous utilisez de l eau disti...

Page 28: ...eurs sont disponibles pour prolonger la dur e de conservation des produits humides Rehausseur Rallonge du robinet de vidange Une rallonge du robinet de vidange peut tre install e en usine en option po...

Page 29: ...TRES aTTEINTES aUX DRoITS DE La PRoPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GaRaNTIES NE CoUVRENT PaS ampoules d clairage incandescence enduites lumi res fluo...

Page 30: ...Form No FSCDm 1016 30 NOTES English...

Page 31: ...Form No FSCDm 1016 31 NOTES English...

Page 32: ...rvice Co maspeth 718 386 2515 appliance Installation Buffalo 716 884 7425 Duffy s Equipment Services Inc Buffalo 800 836 1014 3Wire Northern Plattsburgh 800 634 5005 Duffy s Equipment Services Inc Sau...

Reviews: