FSM-1022
10
Symptom
Probable Cause
Corrective Action
Unit operates, but is not
circulating air inside cabinet.
Blower motor is defective.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
The correct voltage may not be supplied to
blower.
Food cavity not hot enough.
TEMPERATURE Control set too low.
Adjust TEMPERATURE Control to a higher setting.
Heating elements not working.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
TEMPERATURE Control not working
properly.
Excessive air movement around unit.
Restrict or redirect air movement (i.e., air conditioning duct
or exhaust fan) away from unit.
Unit connected to incorrect power supply.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Food cavity too hot.
TEMPERATURE Control set too high.
Adjust TEMPERATURE Control to a lower setting.
TEMPERATURE Control not working
properly.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Unit connected to incorrect power supply.
Unit is heating, but is not
producing humidity inside
cabinet. LOW WATER indicator
is not on and unit is full of water.
Contact an Authorized Hatco Service Agent
or Hatco for assistance.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
Unit is heating, but is not
producing humidity inside
cabinet. LOW WATER indicator
is on and unit is full of water.
Water level sensor not working properly.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
No heat, but light works.
TEMPERATURE Control set too low.
Adjust TEMPERATURE Control to a higher setting.
Heating elements not working.
Contact an Authorized Hatco Service Agent or Hatco for
assistance.
TEMPERATURE Control not working
properly.
No heat and no lights.
Power turned OFF (O).
Move
POWER ON/OFF (I/O) switch to the ON (I) position.
Circuit breaker tripped.
Reset circuit breaker. If circuit breaker continues to trip,
contact Authorized Service Agent or Hatco for assistance.
TROUBLESHOOTING GUIDE
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at
www.hatcocorp.com,
select the
Support
pull-
down menu, and click on “Find A Service Agent”; or contact the
Hatco Parts and Service Team
at:
Telephone: 414-671-6350
e-mail: [email protected]