5.7 THE CFV ON A 500 CAMERA
The 500 setting in the camera body menu (see page 69)
includes the following camera models:
●
500C
●
500C/M
●
501C
●
501CM
●
503CX
●
503CXi
●
503CW
The basic operation is described in the quick start chapter on
Note!
You can release the camera even if the CFV is not ready for a
capture. Please make sure the status LED on the CFV is green
before releasing the camera.
●
Set camera body type to 500 as described on page
START LIVE VIEW WITH A 500C OR 500C/M
CAMERA
1 Set B mode on the lens.
2 On the 500C and 500 C/M cameras, there is a small lever
(time catch) (A) that you can switch from 0 to T position
(B). This will lock the release button in the in position.
3 Press the shutter release.
4 Activate live view
5 Press the Menu button or Play/On-Off button to end Live
View.
6 Move the time catch back to 0 position. The camera will
close again.
START LIVE VIEW WITH 501 AND 503 CAMERAS
1 Set B mode on the lens.
2 Use a lockable cable release (C).
3 Release the camera.
4 Activate live view
5 Press the Menu Button or Play/On-Off button to end Live
View.
6 Free the cable release lock.
Normal mode
Time mode. Release button will be
locked in the in-position.
A
B
C
CFV II 50C USER GUIDE
www.hasselblad.com
50
USING THE CFV
Summary of Contents for CFV II 50C
Page 1: ...CFV II 50C User Guide 2019 12 20 v1 ...
Page 6: ...1 INTRODUCTION ...
Page 15: ...2 QUICK START ...
Page 21: ...3 SAFETY ...
Page 25: ...4 PARTS CONTROLS ...
Page 39: ...5 USING THE CFV ...
Page 68: ...6 SETTINGS ...
Page 98: ...7 PHOCUS ...
Page 106: ...8 ACCESSORIES ...
Page 109: ...9 APPENDIX ...