82
Lighting the Fire Tula direct vent stove
Procedure
Position of Control
Elements
Completely open
secondary air
Open warming up slider
Pull secondary air
slider all the way out
Push warming up
slider upwards
Pile up any remaining ash
and unburned charcoal
into the centre of the
combustion chamber
Open fi re box door
Place 2-3 small logs into
the middle of the fi re box;
stack kindling/ignition
material and approx. 0.5 kg
of dry wood chips on top
Light the kindling/
ignition material.
Close fi re box door
Tab. 2
15. Adding Fuel / Heating at Nominal Thermal Output
More fuel should be added to the fi re when the fl ames from
the previous burning off phase have just gone out.
15.1 Adding Fuel / Heating at Nominal Thermal Output
Tula
Standard
When the fi re is in its fi nal state, bring the fi re box in the
warming up position for approximately 5 to 10 minutes
(see fi g. 6 on previous page).
Afterwards put the secondary air slider in teh required
position.
Adding Fuel / Heating at Nominal Output
Procedure
Position of
Control Elements
Adjust secondary air
Set secondary air slider to
position 4-5
Add two logs weighing
approx. 1.2 kg in total.
Place logs with the end to
the front of fi re box. Only
add a single layer of fuel.
Open fi re box door
Close fi re box door (Fig 7)
Tab. 3
15.2 Adding Fuel / Heating at Nominal Thermal Output
Tula direct vent stove
Adding Fuel / Heating at Nominal Output
Procedure
Position of
Control Elements
Adjust secondary air
Close warming up slider
Set secondary air slider to
position 4-5
Push warming up slider
downwards
Add two logs weighing
approx. 1.2 kg in total.
Place logs with the end to
the front of fi re box. Only
add a single layer of fuel
Open fi re box door
Close fi re box door
Tab. 4
Summary of Contents for Tula
Page 2: ...2 ...