48
12. Technical Data Sendai 135/155 and Sendai 175
The Sendai 135/155 and Sendai 175, certified in compliance with DIN-EN 13240
and Art. 15 a B-VG (Austria)
, can only be operated when the fire box is closed.
Conforms with the DIBt (Deutschen Institut für Bautechnik/German Institute for Build-
ing Technology) approval criteria for direct vent fireplaces for solid fuels.
Multiple
connections to the chimney are possible, see point 4. “Connection of Multiple
Devices in Direct Vent Operation”.
DIBt approval number:
Z-43.12-396 / Typ FC41x and FC51x
The following data applies to the chimney characteristics in accordance with
EN 13384-1 / 2:
Combustion Values*
Wood
Nominal Thermal Output
6
kW
Room heating output
6,6
kW
Exhaust gas temperature
236
˚C
Waste Gas Outlet Temp.
299
˚C
Waste Gas Mass Flow Rate
5.33
g/s
Min. Supply Pressure at Nominal Thermal Output**
12
Pa
Efficiency
83.5
%
CO content
817
mg/Nm³
Particulate
9
mg/Nm³
OGC
66
mg/Nm³
NO
X
99
mg/Nm³
Min. required combustion air volume
25
m³/h
* Test bench performance and values at 13% O
2
** For separate air supply in low-energy houses and insufficient combustion air supply in the room where
the stove is installed.
Dimensions:
Height
Width
Depth
Stove
133/155/175 - 220
cm
37 cm
41 cm
Fire box
61 cm
21 cm
27 cm
Weight Sendai 135
140 kg
Weight Sendai 155 (without heat retaining block)
155 kg
Weight Sendai 175 (without heat retaining block)/Additional module
163/15 kg
Weight 1x heat retaining block flue pipe conection top/rear
63/52,5 kg
¹ Vertical flue pipe length
min. 25 cm
Flue pipe diameter
15 cm
Pipe diameter of Hase ventilation system**
10 cm
Depending on the insulation of the building, the nominal thermal output of
6 kW
indi-
cated on 20 - 80 m² (subject to change).
Summary of Contents for Sendai 135
Page 2: ......
Page 6: ...6 2 Bedienungselemente Feuerraumtürgriff Feuerrostbedienung Luftschieber Aschebehälter ...
Page 15: ...15 D ...
Page 16: ...16 Nous vous souhaitons d agréables moments de détente au coin du feu Hase ...
Page 23: ...23 F 2 1 fig 6 1 fig 5 2 ...
Page 27: ...27 F ...
Page 35: ...35 I 1 fig 5 2 2 1 fig 6 ...
Page 39: ...39 I ...
Page 42: ...42 2 Control Elements Air slider Ash drawer Fire box door handle Grate slide ...
Page 52: ...52 2 Bedieningselementen Luchtschuif Aslade Handvat Bediening van het vuurrooster ...
Page 72: ...72 2 Elementy obsługowe Popielnik Uchwyt drzwiczek paleniska Zasuwa powietrza Dźwignia rusztu ...
Page 94: ...94 ...
Page 96: ......