Attention :
During the mould diagnosis, a weak heating pulse is subsequently given on every zone,
then the temperature increase on that zone is checked. This is done at low temperature
(max. 120°C),
so that normally, no cooling device is required (only for very delicate
moulds).
With a standard mould configuration, the diagnosis can immediately be engaged with
the „Start“-button. Progress of the diagnosis is shown by the coloured marking of every
zone with the result (normally green). If there are still zones left in white, the diagnosis is
not finished yet.
Attention :
As all zones are checked separately one by one in several steps, the whole diagnosis
can take up to half an hour, in exceptional cases even longer.
After start-up of the diagnosis, no input is required, the presence of an operator is not
necessary. Ongoing execution of the diagnosis is shown by a running symbol (rotating
star, lower right corner).
When the mould diagnosis is finished successfully, the result is shown as follows :
In the „Normal view“, the result for each zone is depicted with a colour, a legend on the
right side of the screen explains them.
For more information about the analysis result in one particular zone, press the field of
this zone, the following window then shows up (see next page) :
1
2
3
4
5
6
7
8
9
10
11
12
Diagnosis
ongoing