HASCO hot runner 24
Ad 1.) Display and altering of ACTUAL- resp. SETPOINT-values :
Actual
process temperature
value
Actual
Setpoint temperature value
,
can be altered, when the display
field is touched (see below)
Setpoint value + or - 1°C
Actual
heating current
Actual powersetting
of the controller
Entering new setpoint value
Touching of this field opens the following numpad :
Enter the desired setpoint value with the
keyboard and acknowledge with
„Back“ deletes the last digit
„Clear“ deletes the whole number
„ESC“ aborts the entering process, alternatively,
close the numpad with the red cross
(upper right corner)
Attention:
The entered value must be in a range between the indicated „Min“ and „Max“ limit
values, if not, the value will not be accepted.
These limit values are set in the zones configuration menu (see chapter 6.3.4). To
modify them, the operator must at least have the user rights level „Shift leader“.