![Harvest TEC 030-4670A Operation Manual Download Page 4](http://html1.mh-extra.com/html/harvest-tec/030-4670a/030-4670a_operation-manual_2103734004.webp)
4
Description of Screens & Menus of the Harvest Tec Touch Screen Display (TSD)
This system is calibrated for use with Harvest Tec buffered propionic acid. The use of other products can
cause application problems and damage to system components. The TSD monitor will allow you to set your
bale size, weight, single bale formation time, moisture levels and application rates. The automatic mode will
automatically adjust the application rates as the moisture level changes. Manual mode will allow you to control
the application rates on the go.
Automatic Mode
-
Automatically adjusts preservative application as you bale. The following items are
displayed in the mode while baling: Moisture, Baling Rate, Application Rate (actual and target), Last Bale
Average Moisture, Tons Baled, and Pounds of Product Used.
Manual Model
- Allows the three different pumps to be turned on at a fixed rate as you bale. The following
items are displayed in the mode while baling: Moisture, Baling Rate, Application Rate (actual only), Last Bale
Average Moisture, Tons Baled, and Pounds of Product Used. This mode can also be used to prime the pumps.
Setup Mode
- Allows the operator to customize the applicators settings for their baler and baling needs. This
mode allows changes to be made to the following areas: Application Rate, Baling Rate, Language, US or
Metric units, and turn on/off the optional Hay Indicators.
Diagnostics
- Allows operator to set date and time and calibrate the touch screen. The installed software
versions can also be viewed here.
Job Records
- Keeps track of up to 63 plus jobs with total product used, average moisture content, highest
moisture content, tons baled, date of baling, and total number of bales made. Individual bales are also able to
be viewed and the records can also be downloaded to a USB drive in this mode.
Power Off
- Will
power down the display only. The application unit will not fully power down unless the keyed
power is turned off. Press anywhere on the screen to power back on (with the key on).
To view a complete Wiring Diagram and Pin Outs, refer to your Installation or Operation Manual.