Manual Mode  

 
After pushing the MANUAL MODE key in the Main Menu screen, the following screen will appear: 
 

 

 
 

1.  Push the START/STOP key to pause the system while in operation. 
2.  Push the OVERRIDE key to turn on all three pumps at the same time for full output of the system. Use 

this mode when going through a short area of wet crop. 

3.  In Manual Mode you can turn the pumps on or off by pressing the underlined area next to the pump 

numbers. In Manual Mode (regardless of moisture, baling rate or bale weight) the outputs of the pumps 
are fixed rates as follows:  
 

Round Balers 

Pump 

Low Tips Output 

(Lbs / HR) 

High Tips Output 

(Lbs / HR) 

 

45 

75 

 

90 

140 

 

135 

265  

 

 

 

 

Small Square Balers 

Pump 

Low Tips Output 

(Lbs / HR) 

High Tips Output 

(Lbs / HR) 

 

25 

40 

 

75 

75 

 

145 

205 

 

4.  The moisture content is shown in the upper right hand corner. 
5.  Baling rate and Application rate are shown in the middle. The output of a pump can be checked by 

dividing the preset output (shown in step 3) by the displayed baling rate.  

6.  Volume used shown at the bottom of the screen will show accumulated pounds of preservative used on 

the go. This number will reset at power down, but remains in the job record screen. 

NOTE: Initial start-

up requires pressing the New Job key in the Job Records screen in order for Volume Used 
accumulation to be recorded

This only needs to be done once on initial start-up of system and 

not every time the system is started for operation.

 (See JOB RECORDS screen) 

7.  The baling rate is set in the SETUP MODE menu.   
8.  This graph shows the moisture trend from the last 90 seconds of baling (one reading every 3 seconds). 
9.  This button is your contrast control. Press this button to darken the screen. When the screen reaches 

its darkest point, when the button is next depressed it will return to lightest setting. 

10. Press the MAIN MENU key to return to the opening screen.

 

 
 
 

5.8 

10 

 

Summary of Contents for 030-4670A

Page 1: ...1 4670A OPR 11 15 Operation Manual 030 4670A Touch Screen Display TSD for 400 Series Forage Harvester...

Page 2: ...s 8 First Time and Annual Startup Instructions Checking and Priming the Pumps 9 9 Setting Up System for Initial Use 10 11 Application Rate 10 Selecting High or Low Tips 10 Baling Rate 11 Operating Ins...

Page 3: ...If you are unsure about operating the system after consulting this manual contact your local authorized dealership for additional assistance If you are in need of parts for the system please see your...

Page 4: ...g Moisture Baling Rate Application Rate actual only Last Bale Average Moisture Tons Baled and Pounds of Product Used This mode can also be used to prime the pumps Setup Mode Allows the operator to cus...

Page 5: ...5 Screen Menus Use the below listed screen menus to navigate through all of the operation screens Automatic Mode...

Page 6: ...6 Manual Mode...

Page 7: ...7 Setup Mode Round Balers Small Square Balers Round Balers Small Square Balers...

Page 8: ...8 Diagnostics Job Records...

Page 9: ...8 Small Square Balers Pump Low Tips Output Lbs Ton High Tips Output Lbs Ton 1 1 2 1 6 1 8 2 6 2 3 6 5 0 3 6 5 0 3 6 7 9 3 9 5 13 4 5 Turn pump 1 on P1 To do this press the underlined area on the scree...

Page 10: ...of the underlined numbers to the right of RATE The key pad shown on the bottom left will display Remember level 1 must be lower than level 2 and level 2 must be lower than level 3 Harvest Tec product...

Page 11: ...to adjust the weight of your bales The key pad shown on the right side will display Press any number combination in this screen within the min max limits Press the ENTER key to save this information 3...

Page 12: ...e The operator sets the target application rate in the setup mode the actual rate should be within one pound when running The baling rate is also set in Setup Mode 5 Volume used shown at the bottom of...

Page 13: ...ication rate are shown in the middle The output of a pump can be checked by dividing the preset output shown in step 3 by the displayed baling rate 6 Volume used shown at the bottom of the screen will...

Page 14: ...revious jobs is done by pressing the UP or Down keys 3 Every time the NEW JOB key is pressed the accumulated pounds on auto and manual modes will be reset to zero After 63 jobs have been stored the ne...

Page 15: ...here is preservative in the tank and ball valve is in the open position B Air in lines Pump will not prime Check for leak in lines or defective check valve C Pump is working but not producing desired...

Page 16: ...ride turns on all three pumps at full output The pumps will remain at full output until the operator turns these pumps off by pressing the OVERRIDE key again 5 The flow meter reading is more or less t...

Page 17: ...corrosion or poor contact 2 Apply dielectric grease to all connections 3 Check power supply at tractor Voltage should be constant between 12V and 14V 3 Install voltage surge protection on tractors al...

Page 18: ...Output lbs hour 462 High 180 Low 150 Parts Breakdown Touch Screen Display TSD Problem Possible cause s Solution s System does not pause at end of row 1 Short in cable 1 Replace cable Bale rate display...

Page 19: ...y kind direct consequential or contingent to persons or property Furthermore this warranty does not extend to loss of crop losses caused by delays or any expense prospective profits or for any other r...

Page 20: ...20 HARVEST TEC INC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Reviews: