5)  2INPUT or Dual Input Controlled Output. The software needs to know which two inputs to 

use and what their polarity is to be.  You are prompted first for the input A: 

    

    12 CHOOSE INPUTA * 

    Input 3 

Choose the input using the up arrow then pressing Ok, then set polarity of InputA must be 

set. There are two choices: 

WHEN INPUT 3 ON *       or     WHEN INPUT 3 ON 

Output 12 OFF?                 Output 12 ON?  

Select the first option if you want the output to be ON when the input is OFF. Once selected 

with the Ok button you will be prompted for the input number for the output OFF. 

    

12 CHOOSE INPUTB * 

Input 4 

Set the input number and press Ok. Enter the polarity of this input control.  

WHEN INPUT 4 ON         or     WHEN INPUT 4 ON * 
Output 12 OFF?                 Output 12 ON?  

Select the first option if you want the output to turn OFF when input is ON. 

The example (two level tank switch), would cause output 12 to turn ON when input 3 goes 

to OFF (low), then turn OFF when input 4 goes to ON (full). 

 

6)  INBURST or Input Controlled Burst Output. Select the input to control it 

13 CHOOSE INPUT   * 
Input 5 

Set desired input, press Ok.  Select the polarity of the input.   

    

WHEN INPUT 5 ON         or     WHEN INPUT 5 ON   * 

Output 13 OFF?                 Output 13 ON? 

Select one then enter the duration 

   

13 DURATION Secs  * 

0020 

The number of seconds is the length of the burst.  If we chose the options marked (*) then 

Output 13 would turn on for 20 seconds each time input 5 changed from Off to ON. 

 

 

Hints for Setting up Green House 

 

Step 1/ Make sure the room is the right size. . The ceiling should be at least 5’ high. 

 

Step 2/ Enclose the room. Make sure furniture, curtains etc are not in the room as they harbour fungi. 

 

Step 3/ Cover walls, ceiling and floor with material like flat white paint or whitewash, or white plastic 

lining. A 1,000 watt HID will efficiently illuminate a 10’x10’ room with a light balancer. . 

Maximise the light using a reflective hood. The more reflection the better. 

 

Step 4/ Set up vent fan. An exhaust fan, vented outside pulling in new fresh air. A small oscillating fan 

for air circulation in the room. Not too close to the plants. Could cause windburn on tender plants. 

 

Step 5/ Irrigation, it’s much easier to run a hose with an on/off valve or install a hose bib in the room. 

Remember once your plants are growing a 10’x 10’ garden may need as much as 30 gallons of 

water. Harvest-master can be used for the watering system with a timer switch or moisture sensor.  

 

Step 6/ A floor drain is handy. Trays placed underneath or visqueen plastic to save floors from damp. 

 

 

 

Summary of Contents for Climate

Page 1: ...4 Models Climate Climate Pro with CO2 sensor Climate Plus Pro Plus with CO2 sensor...

Page 2: ...g 6 Harvest Master Plug and Run pg 8 Set up Equipment pg 10 Set up Climate Information pg 11 Set up Growth Cycle pg 14 Set up Outputs on Plus model only pg 16 Hints on Setting up Greenhouse pg 19 Equi...

Page 3: ...ing how they work in YOUR green room Then I can predict what will happen when I operate them I look after light temperature atmosphere humidity and CO2 I do it all continuously and automatically That...

Page 4: ...is controlled by a 10ft 3m RCA connector lead Temp and Humidity sensor High accuracy microchip type The Pro and Pro Plus models include a CO2 sensor All units are powered by 12vDC 750mA power pack Pow...

Page 5: ...for relay coil activation shall be provided from CLASS 2 power supply only C UL USA certificate E242389 tested to meet or exceed UL and CE standards Sensor Unit Temperature and Humidity Connected to...

Page 6: ...6 Input Connections...

Page 7: ...7 Output Connections...

Page 8: ...un a control cable from the relay to Harvest Master and connect it to the CO2 output 4 Cooling Device Connect an air conditioning unit to a relay and plug the relay into a power outlet Run control cab...

Page 9: ...the end of Calibration and Climate Analysis Harvest Master begins its normal climate control mode If there were devices shown in the connection list that could not be found Harvest Master will displa...

Page 10: ...emperature that the controller will turn lights off even during the Day part of the cycle to protect against plant damage Exceeding this temperature also sets the temperature alarm state Default is 38...

Page 11: ...value enter 3000 6000ppm min if the controller has lost the CO2 dispense rate Symptoms are when CO2 levels do not get high enough even though there is plenty of CO2 This value is continually relearne...

Page 12: ...tries again If it gets three Not enough CO2 attempts in a row it suspends CO2 It will not try again until the next day starts You can start CO2 again by using the CO2 state menu option to change the...

Page 13: ...joined The outputs can be configured as one of six different types Explanation 1 Timer Output This is a simple timer that you enter a Start time and a Stop time 2 Periodic Output This output has a sta...

Page 14: ...10 START TIME 10 45 Set the start time desired then OK Next entry is the period between the start of each cycle 10 PERIOD MINS 00 10 The value is minutes and seconds Press Ok The software will prompt...

Page 15: ...tput 13 OFF Output 13 ON Select one then enter the duration 13 DURATION Secs 0020 The number of seconds is the length of the burst If we chose the options marked then Output 13 would turn on for 20 se...

Page 16: ...tts of power The object is to maintain steady breeze in the room to keep air circulating over the leaves This provides fresh carbon dioxide as it is used up in air around the leaves and removes water...

Page 17: ...be a serious fire risk A Domestic electrical circuit can power a total of just over 2000w at 240v 1800w at 120v A small Green House with 1x 1000watt light fans a dehumidifier and carbon dioxide could...

Page 18: ...s warranty if there has been any attempt to tamper with or disassemble the controller or components This warranty does not cover and TCS will not be liable for any direct or contingent damage or loss...

Reviews: