Protective Ground
Terminal
CAUTION
Refer to Manual
!
!
CAUTION: Not for clinical use on human patients.
Harvard Apparatus PHD ULTRA
™
Syringe Pump Series User’s Quick Start
Publication 5419-001-REV-E
Fuse Holder
Main Power Switch
Connector for Remote
Mechanism
(option)
Analog Control Connector
(option)
RJ11 Connectors for RS-232
(option)
User I/O Connector
Footswitch Input
(switch sold separately)
Universal Power Input
RS-485 Connectors
(For pump-to-pump communication)
RS-232 Serial Input
USB Serial Input
(For communication
from PC)
Half nut Release Knobs
Syringe Holder
Bracket Clamp
Knobs
User Interface /
Touchscreen
Run LED
Guide Rods
Vertical Foot
Support
Mechanical
Stops
Lead screw Pusher Block
Syringe Barrel Clamp
Figure 2: Rear view of the PHD ULTRA
™
.
Figure 3: Battery Insulator must be removed before use.
Figure 1: Front view of the PHD ULTRA
™
.
Features of the PHD ULTRA
™
PHD ULTRA
™
Safety Information
Please read the following safety precautions to ensure proper use of
your syringe pump. To avoid potential hazards and product damage,
use this product only as instructed in this manual.
To Prevent Hazard or Injury:
Use Proper Line Cord
Use only the specified line cord for this product and make sure line
cord is certified for country of use. The operating voltage range for
the PHD ULTRA
™
is 100-240 vac, 50/60 Hz.
Ground the Product
This product is grounded through the grounding conductor of the
power cord. To avoid electric shock, the grounding conductor
must be connected to earth ground. Before making any connections
to the input or output terminals of the product, ensure that the
product is properly grounded.
Make Proper Connections
Make sure all connections are made properly and securely. Any
signal wire connections to the unit must be no longer than 3 meters.
Observe all Terminal Ratings
Review the operating manual to learn the ratings on all connections.
Use Proper Fuse
Use only specified fuses with product.
Avoid Exposed Circuitry
Do not touch any electronic circuitry inside of the product.
Do Not Operate with Suspected Failures
If damage is suspected on or to the product do not operate the
product. Contact qualified service personnel to perform inspection.
Place Product in Proper Environment
Review the operating manual for guidelines for proper operating
environments.
Observe all Warning Labels on Product
Read all labels on product to ensure proper usage.
(For communication
from PC)
*Power Source
When powering a pump in a
chain through an RS-485 cable,
toggle switch to RS-485.