4-2
RF-7800W
TROUBLESHOOTING AND MAINTENANCE
R
NOTE
The Telnet session must connect to the RF-7800W HCLOS
Radio within approximately 20 seconds from when the radio
starts responding to pings. Logging into the default IP Address
will cause the unit to be reset to the factory default
configuration.
i.
Enter the following to log in:
1.
User Name - type
admin
and press
[Enter]
.
2.
Password - type
admin
and press
[Enter]
. The password characters do not echo to the computer
screen.
j.
Enter the command
save defaultconfig
and press
[Enter]
to ensure that all parameters are set to default
values.
k.
Enter the following commands to set a new IP address. A
192.168.26.2#
prompt is shown at each step.
1.
set ipaddr <IP Address>
followed by
[Enter]
.
Note the spaces in this example:
set ipaddr 192.168.100.1
2.
save config
followed by
[Enter]
. The message, “Connection to host lost.” will display.
l.
Select the
user
command to enter new user name and password information, if required.
Figure 4-1. Factory Default Reset Time Frame
CL-0426-4200-0020
POWER OFF
8 TO 10
SECONDS
POWER ON
GREATER THAN
2.5 MINUTES
POWER ON APPROX.
2 MINUTES 40 SECONDS
AND BEGIN
TELNET SESSION
Summary of Contents for RF-7800W-OU49 series
Page 3: ......
Page 5: ......
Page 15: ...x RF 7800W SAFETY SUMMARY R This page intentionally left blank...
Page 38: ...3 7 RF 7800W SYSTEM ADMINISTRATION AND CONFIGURATION R Figure 3 4 System Configuration...
Page 64: ...3 33 RF 7800W SYSTEM ADMINISTRATION AND CONFIGURATION R Figure 3 18 File Management...
Page 67: ...3 36 RF 7800W SYSTEM ADMINISTRATION AND CONFIGURATION R This page intentionally left blank...
Page 73: ...4 6 RF 7800W TROUBLESHOOTING AND MAINTENANCE R This page intentionally left blank...
Page 83: ...A 6 RF 7800W APPENDIX A R This page intentionally left blank...