Power Output
5000W
4000W
3000W
2000W
1000W
500W
PA Volts
96.0
87.0
76.0
62.0
48.5
37.0
PA Amps
57.5
52.5
46.0
38.5
29.5
22.5
PDM Level
6.7
6.0
5.3
4.5
3.4
2.5
Supply Voltage
247
250
252
255
259
262
Supply Current
24.1
20.0
15.8
12.0
6.8
4.2
RF Drive
8.7
8.7
8.6
8.5
8.4
8.3
VSWR Detector Null
0
0
0
0
0
0
VSWR Detector Null Set
5.1
5.1
5.1
5.1
5.1
5.1
Underdrive Set
6.7
6.0
5.3
4.4
3.3
2.5
Supply Current Set
44.8
44.8
44.8
44.8
44.8
44.8
Supply Voltage Set
297
297
297
297
297
297
Battery
9.8
9.8
9.8
9.8
9.8
9.8
The readings above are typical readings. Refer to the Factory Test Data Sheets supplied for readings actually obtained during factory
tests.
Table 2-9. GATES FIVE
Typical Readings at 920kHz
Rev. AC: 2/29/00
888-2314-001
2-11
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Gates Five 994 9204 002
Page 4: ......
Page 6: ...iv 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Page 8: ...vi 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Page 28: ...2 12 888 2314 001 Rev AC 2 29 00 WARNING Disconnect primary power prior to servicing...
Page 76: ...C 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 82: ...E 4 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 88: ...F 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 96: ...H 2 888 2314 001 Rev AA 8 18 1999 WARNING Disconnect primary power prior to servicing...
Page 104: ...K 2 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 108: ...L 2 888 2314 001 WARNING Disconnect primary power prior to servicing...