Changing the default failsafe account username and password is
highly recommended. If you choose to do so, please remember
the username and password as this information cannot be
recovered by Extreme Networks.
Would you like to change the failsafe account username and
password now? [y/N]: <
Enter
>
Would you like to permit failsafe account access via the
management port? [y/N]: <
Enter
>
Since you have chosen less secure management methods, please
remember to increase the security of your network by taking
the following actions:
* change your admin password
* change your failsafe account username and password
* change your SNMP public and private strings
* consider using SNMPv3 to secure network management traffic
* X250e-24t.1 #
Setting Switch IP Address
Once the switch prompt appears, the following command may be used to set the switch’s IP
address to 192.168.100.2, which is compatible with the default Leitch/Harris router IP
address and subnet settings (address=192.168.100.250, subnet=255.255.255.0). Press
<
Enter
> at the end of each line to execute the command:
X250e-24t.1
#configure vlan "default" ipaddress 192.168.100.2/24
Enabling Other IP Settings
Press <
Enter
> at the end of each line to execute the command.
•
To enable a compatible default gateway address, use the following command:
X250e-24t.1
#configure iproute add default 192.168.100.1
•
To enable the remote web management interface, use the following command:
X250e-24t.1
#enable web http