GPI Input_1 [RO]
Displays whether or not GPI Input 1
has been switched to In 1
• N/A
• Switch to A1
GPI Input_2 [RO]
Displays whether or not GPI Input 2
has been switched to In 2
• N/A
• Switch to A2
GPI Input_3 [RO]
Displays whether or not GPI Input 3
has been switched to Relay Bypass
• N/A
• Relay Bypass
GPI Output_1 [RO]
Displays whether or not the output is
set to IN_1
• N/A
• Input IN_1 on line
GPI Output_2 [RO]
Displays whether or not the output is
set to IN_2
• N/A
• Input IN_2 on line
GPI Output_3 [RO]
Displays whether or not the relay
bypass has been activated
• N/A
• Signal Bypass
Video
LOV Mode
4, 1
Determines the processing mode when
there is a loss of video on the selected
input
• Pass
• Black
•
Freeze
Still Image Mode
4, 2
Forces the output to a still image (see
•
Auto
• Force
Still Image Source
4, 3
Selects the source for the still image
• Trouble Slide
•
TSG
• None
Test Signal Generator
Pattern
4, 4
Selects the TSG pattern
• Black
•
75% Color Bar
• 100% Color Bar
• H Sweep
• Multiburst
• Ramp
Thumbnail Source
4, 7
Sets the thumbnail source
• In 1
• In 2
•
Frame Sync
Video > FS Settings
H Phase
4, A
Sets the Frame Sync horizontal phase
Note
Available options depend on the
system’s set video standard.
<set video standard>
V Phase
4, B
Sets the Frame Sync vertical phase
Note
Available options depend on the
system’s set video standard.
<set video standard>
Table 8-2. ACO6800
+
ISCST SDI Parameters (Continued)
Group
Parameter Name
Bank,
Switch
Function
Options