Harrie Leenders Cylon Instructions for Installation, Use and Maintenance
19
Installation instructions
·
All local regulations including those referring to national and European standards
must be observed when installing the appliance.
·
Ensure there is sufficient ventilation / air supply in the room from which your stove
gets the combustion air. This is the room where the stove is installed if you do not
use a wall or stovebase airsupply system.
·
The stove is not suitable for a shared flue system.
·
Ensure adequate access for cleaning the appliance, the flue gas connection and the
chimney.
·
When installing the stove, take into account the minimum distances from the wall so
as to avoid any fire risk. The minimum distances (sizes in mm) are shown in the
figure below.
Specifications Cylon
Nominal power of the stove is 10 kW.
Flue gas mass flow = 7.4 g/s
Appliance weight = 110 kg
Minimum chimney draught = 8.0 Pa
Flue gas temperature directly over the stove = 242 °C
1
0
0
0