![Harnisch+Rieth D-LE 255 S Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/harnisch-rieth/d-le-255-s/d-le-255-s_operating-instructions-manual_3961001018.webp)
Maschinenbau
Werkzeuge
Laborgeräte
air channels, channel 1 and channel 2.
5.2.2 Display messages for "air velocity" (m/s) control variant
/ 4 0
2 0
m/ s
2 0 m/ s
/
/0
1
2
A) Two Ø40 air channels are open
(two stop valves are open). If Ø50
is selected in the second chan-
nel, the airflow is increased as if
both channels had a Ø50 diame-
ter to maintain 20 m/s in each
channel. The display shows Ø50.
//
/0 4 0
2 0
m/ s
2 0 m/ s
2
1
B) Only one Ø40 channel is open
(only one stop valve is open the
second stop valve is closed)
4 0
//
/0
2 0
m/ s
2 0 m/ s
2
1
C) A channel is open (only
one stop valve is open, the sec-
ond is disabled in the user menu)
Fig. 14 Display messages for "air velocity" (m/s) control variant
//
/0 4 0
2 0
m/ s
2 0 m/ s
2
1
D11
D2
D12 D13 D14
D6
D7
D8
D10
D9
Fig. 15 Display message components for "air velocity" (m/s) control variant
D
2
Air channel No. 1 is active (i.e. there is
airflow in the extraction tube).
The arrow indicates that the connected dust-generating
device is detected and the extraction unit is opera-
tional. Simultaneously, the stop valve has enabled the
airflow.
D
6
Ultra-fine filter contamination degree.
Allows a visual assessment of the ultra-fine filter con-
tamination.
D
7
Pre-filter
contamination
degree (filter
bags).
Allows a visual assessment of the pre-filter contamina-
tion.
D
8
Symbol for pre-filter (filter bags).
-------------
D
9
Symbol for ultra-fine filter.
-------------
D
10
Channel number
It is possible to connect two workplaces. Thus, two air
channels, channel 1 and channel 2.
D
11
Diameter of the connected extraction
tube (connecting tube ID Ø40mm)
The tube diameter is defined in the user menu.
D
12
Measured air speed in a single tube.
Indicates the actual air speed per tube. It corresponds to
the air basis (m/s) as per configuration.
D
13
Extraction tube without airflow
In this case, the stop valve is closed (the dust-
generating equipment has not been activated).
D
14
Air basis (m/s)
The desired air velocity in the extraction tube (m/s) is