Maschinenbau
Werkzeuge
Laborgeräte
6.
Hose/tube diameter 1
40, 45, 50, 60 mm
40 mm
7.
Hose/tube diameter 2
40, 45, 50, 60 mm
40 mm
8.
Air basis (m / s)
15 to 50 m/s
20 m/s
9.
Language
De, En, Fr, Es
De
10.
Sensitivity
255
100
A n w e n d e r me n ü
L u f t b a s i s ( L / s ) : 2 0 L / s
F r e i g a b e 1 :
R o h r 1 : 4 0 mm
L u f t b a s i s ( m/ s ) : 2 0 m/ s
E mp f . 1 : ( 1 5 3 ) . 1 0 0
A b s t a n d l i n k s 1 : 0 4 0
S p r a c h e D e
A) User menu
The user menu of the single-
workplace extraction unit consists
of only one page.
A n w e n d e r me n ü 1 / 2
L u f t b a s i s ( L / s ) : 2 0 L / s
F r e i g a b e 1 :
F r e i g a b e 2 :
R o h r 1 : 4 0 mm
R o h r 2 : 4 5 mm
L u f t b a s i s ( m/ s ) : 2 0 m/ s
E mp f . 1 : ( 1 5 3 ) . 1 0 0
A) User menu Page 1
A n w e n d e r me n ü 2 / 2
A b s t a n d l i n k s 1 : 0 4 0
E mp f . 2 : ( 0 4 4 ) 2 0 0
A b s t a n d l i n k s 2 : 0 4 0
S p r a c h e D e
B) User menu Page 2
The user menu of the double-
workspace extraction unit consists
of two pages.
Fig. 10 User menu - original illustration
5.1 Changing the user menu settings
MF
45
42
46
44
43
Fig. 11 User menu operation keys
•
Use the keys "
m
"(45) and "
l
"
(44)
to position the cursor on the setting you wish to change.
•
Use the keys "+" (42) or "" (43) to change the value as required.
-
Air basis (l/s)
: Desired airflow volume in an extraction channel.
-
Enable 1 (2)
: Enable extraction channel 1, 2, or both. Symbols: "
"Means Enable, "
X
" means
disable.
-
Tube 1 (2)
: The diameter of the connected hoses (tubes) will be provided to the dust-generating
device.
-
Air basis (m / s)
: Desired airflow speed in a tube.
-
Recommended 1 (2):
Response threshold for extraction unit. The response threshold should be
set above the value displayed in parentheses before. All connected dust-generating devices
must be in
standby
mode to define the response threshold correctly.
The point displayed between the value in parentheses and the respond threshold indicates that the
start-up signal was issued to the extraction unit.
-
Distance to the left:
The parameter is possibly redefined after consultation with H+R.
-
Language: