5 Blasting chamber illumination (24 V)
(See fig. 3, page 7)
The blasting chamber illumination (18) is operated with a safety low voltage of
24 volts.
Note
When exchanging the tubular lamp press both contacts (holder) slightly apart.
Before inserting a new tubular lamp press both contacts (holder) slightly
together to fasten the lamp securely.
6 Electrical fuse protection
(See fig. 2 page 6)
−
The fuse for feeble currents 2,5 A/T (50) for the transformer is located on the
bottom side of the unit (blasting chamber illumination, automatic deactivation
device).
−
The two main fuses (0.315 A/T) are built into the mains connection socket (15).
7 Accessing the electrical/pneumatic control system
(See fig. 2 page 6)
The electrical/pneumatic control system is located on the bottom side of the
unit in the front floor compartment (33).
Danger
Before opening the front floor compartments (33) switch off unit at main switch
(12) and pull the mains supply plug.
−
Removing the 10 screws (34) opens the front floor compartment.