46 Alarms for the NSG Unit
CHAPTER 3
Web client
:
GbE X SFP not
mounted
Control panel
:
SFP not mounted.
The SFP module is
missing or not properly
mounted.
For an NSG with
automatic redundancy
enabled:
■
If this failure occurs
on the active GbE
channel, a
redundancy switch
is triggered.
■
If this failure occurs
on the backup GbE
channel, you
receive notification
in the alarm list and
alarm log, but the
Alarm LED does not
turn red.
■
Verify that an SFP
module is present and is
properly mounted in
GbE X (X=1 or 2).
Web client
:
GbE X No Valid
MPEG Stream in
Input
Control panel
:
No Valid MPEG In
The data received
through the GbE port is
not a valid MPEG
stream. Typically, the
GbE stream does not
contain PAT.
Check the GbE source for
content and/or
encapsulation problems.
Web client
:
GbE X UDAD
Ethernet Connection
Failed
Control panel
:
UDAD conn failed
The NSG could not
establish Ethernet
connectivity with the
switch.
Check if the switch's
management IP address
matches the one shown on
the NSG's Input
configuration page.Check if
the switch is connected to
the management LAN.
Web client
:
GbE X UDAD Telnet
Connection Failed
Control panel
:
UDAD conn failed
The NSG could not
establish Ethernet
session with the switch.
Check if Telnet is enabled
on the switch.
Alarm Message
Description
Solution
Summary of Contents for NSG 9108
Page 6: ...vi Table of Contents...
Page 26: ...18 Back Panel CHAPTER 1...
Page 60: ...52 APPENDIX A...
Page 71: ...63 Advanced Fiber Optic Connections Cascading with IP Switching...
Page 73: ...65 Advanced Fiber Optic Connections Connecting a DWDM...
Page 74: ...66 Connecting a DWDM APPENDIX C...
Page 76: ...68 Contacting Harmonic for Technical Support APPENDIX D...
Page 80: ...VAM Glossary 72...