33
Cabling and Configuration
Preliminary Configuration of the NSG
The program check whether the network group parameters are valid
and only then applies the changes. The ETH2 IP Address screen
appears.
If invalid network parameters are entered an error message appears.
PHY Configuration
When configuring the physical layer (PHY), select either of the following
options for each ETH ports:
■
Auto Neg - a handshake protocol used in Ethernet links. It must be
selected if the other end of the Ethernet link also uses auto
Negotiation. Selecting this protocol while communicating with a
device that does not use it causes communication problems.
■
100 BT full - sets the speed to 100 BT and communication mode to
full duplex.
■
10 BT full - sets the speed to 10 BT and communication mode to full
duplex..
■
100 BT half - sets the speed to 100 BT and communication mode to
half duplex.
■
10 BT half - sets the speed to 10 BT and communication mode to half
duplex.
To set PHY configuration for ETH1:
Once you are in Config mode, do the following:
1.
Navigate to the Network Config screen and click <Enter>.
The Ethernet Port 1 screen appears.
2.
Click <Enter>. The ETH1 IP Address screen appears.
3.
Click <Down or Up> until the ETH1 PHY Config screen appears.
4.
Click <Enter>. The Edit PHY Config screen appears.
5.
Using the <Down or Up> keys select the required option.
6.
Click <Enter> to apply changes and to return to the ETH1 PHY Config
screen.
Summary of Contents for NSG 9108
Page 6: ...vi Table of Contents...
Page 26: ...18 Back Panel CHAPTER 1...
Page 60: ...52 APPENDIX A...
Page 71: ...63 Advanced Fiber Optic Connections Cascading with IP Switching...
Page 73: ...65 Advanced Fiber Optic Connections Connecting a DWDM...
Page 74: ...66 Connecting a DWDM APPENDIX C...
Page 76: ...68 Contacting Harmonic for Technical Support APPENDIX D...
Page 80: ...VAM Glossary 72...