background image

Harman®  •  XXV Installation Manual_R23  •  2004 -___  •  08/13

2 3

3-90-00684i

B. wiring Diagram

WHITE or LT BL

UE

GREEN USED ON ACCENTR

A ONLY

2

1

DISTRIBUTION BLOWER

DK BLUE or BLA

CK

IGNITER ELEMENT

INSIDE BURNPO

T

OUTBO

ARD

FEEDER MO

TOR

ST

AND

ARD USE 

W

AT

TS - 180 @ 120V

AC 60H

z = 3.6 A

M

AX 

W

AT

TS - 440 @ 120V

AC 60H

z = 4.2 A

LOW PRESSURE SWIT

CH

LT.BL

UE

N.O

.

CONT

AC

TS

COMBUSTION MO

TOR

LT

.BL

UE

M

ALE/FEM

ALE C

ONNEC

TIONS

1

3

2

WHITE

PL

UGGED

BR

OWN

5

6

7

EMPT

Y

WHITE

WHITE

WHITE

4

8

10

9

RED

BL

UE

YELL

OW

PAR

T NO

. 3-90-00877

BLA

CK

11

WHITE 11 PIN PLUG

M

ALE/FEM

ALE C

ONNEC

TIONS

GREEN 

WIRE IS GR

OUND

BONDED 

TO ST

OVE FR

A

ME

18/3 RUBBER C

ORD

POWER C

ORD

HARM

AN -  A

CCENTR

A, X

XV

, P35I  PELLE

T ST

OVE 

WIRING DIA

GR

A

M

ESP 

CONTR

OL

BO

ARD  

BR

OWN

M

ALE/FEM

ALE C

ONNEC

TIONS

WHITE

WHITE

WHITE

DK BL

UE

RED

GREEN

WHITE

REMO

TE SENSOR POR

TS

YELL

OW

BLACK

6 A

MP GLASS FUSE

ESP PR

OBE

3 4

1

5

6

8

11

10

9

AC

C/

XX

V

ST

AND

ARD

FEEDER MO

TOR

P35I

AC

C/

XX

V

ROOM 

SENSOR TERM.

P35I

Summary of Contents for XXV Freestanding Pellet Stove

Page 1: ...ng codes prior to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspec...

Page 2: ...Non Combustible Materials Specification 4 F Combustible Materials Specification 4 G Electrical Codes 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies Needed 6 C Ins...

Page 3: ...roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided to the...

Page 4: ...listing will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without full...

Page 5: ...vent termination CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufa...

Page 6: ...ructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair...

Page 7: ...2004 ___ 08 13 7 3 90 00684i 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference only 31 119 28 406 29 429 4 041 12 417 8 623 14 715 28 5...

Page 8: ...tibles When selecting a location for the appliance it is important to consider the required clearances to walls see Figure 3 2 WARNING Risk of Fire or Burns Provide adequate clearance around air openi...

Page 9: ...l Other floor protector materials are ceramic tile stone brick etc Mobile Home Installation When installing this unit in a mobile home several requirements must be followed Reference HUD Regulation 24...

Page 10: ...ethod This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high a...

Page 11: ...ting fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you...

Page 12: ...vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 7 Installing into an...

Page 13: ...ugh the ceiling Through the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through Seal pipe joints with silicone or aluminum tape in addition to the sealin...

Page 14: ...y is fully open on a minimum of 2 sides beneath the floor NOTE where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Can...

Page 15: ...hich the pellet appliance is located Consult with your local HVAC professional to determine the ventilation demands for your house C Venting Use of Elbows A combustion blower is used to extract the co...

Page 16: ...e demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult wit...

Page 17: ...g should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed F Draft Draft is the pressure difference needed to ven...

Page 18: ...mends Installing the pellet vent with a minimum vertical run of five feet preferably terminating above the roof line Installing the outside air intake at least four feet below the vent termination To...

Page 19: ...ny parts damaged in shipment Read all the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit Installation an...

Page 20: ...guide on top of the burn pot Make sure that the flame guide is fully seated on the vertical sides of the burn pot and that the back of the guide rests against the body of the stove Figure 5 3 INSTALL...

Page 21: ...his voltage adjustment allows the installer to change the low voltage set point approximately 10 volts This adjustment should be done by the installer during set up because a draft meter reading is re...

Page 22: ...hey are in the same room as the stove Clothing and other flammable materials should not be placed on or near this stove Installation and repair of this stove should be done by a qualified service pers...

Page 23: ...BLUE MALE FEMALE CONNECTIONS 1 3 2 WHITE PLUGGED BROWN 5 6 7 EMPTY WHITE WHITE WHITE 4 8 10 9 RED BLUE YELLOW PART NO 3 90 00877 BLACK 11 WHITE 11 PIN PLUG MALE FEMALE CONNECTIONS GREEN WIRE IS GROUN...

Page 24: ...U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For...

Reviews: