background image

3

PP38+ Pellet Stove

3-90-08422R33_06/13

Safety Information     

 

 

5

Installation   

 

 

 

6

Venting 

 

 

 

 

8

ESP Control              

 

 

15

Operation   

 

 

 

16

Draft Test Procedure 

 

 

19

Maintenance  

 

 

 

20

Troubleshooting 

 

 

 

25

Specifications 

 

 

 

26

Options 

 

 

 

 

27

Corn/Pellet Mixture   

 

 

28

Fuel Specification Details   

 

29

Wiring Diagram 

 

 

 

30

Warranty 

 

 

 

 

31

Service Parts  

 

 

 

33

table of contents

introduction

Safety Listing: Omni-Test Laboratories, Inc.

Report # 135-S-21-6.2

Tested to: ASTM E1509-04, ULC S627-00, and 

ULC/ORD-C1482-M1990. 

This appliance is also approved for installation 

into a shop.

Division of Hearth & Home Technologies

352 Mountain House Road

Halifax, PA 17032

warning

do not connect to anY air distribution duct 

or sYsteM.

warning

do not use cheMicals or Fluids to start the 

Fire. do not burn garbage or FlaMMable 

Fluids such as gasoline, naPtha, or oil.

This label is located on the back of the unit. 

Please copy the Serial Number for future reference.

Serial #:

"PREVENT HOUSE FIRES"

Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions.

Contact Local Building or Fire Offi cials About Restrictions and Installation Inspection in Your Area.
WARNING : THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL,

AND CEILING/ROOF MUST BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
An outside combustion air inlet must be provided. Refer to Manufacturer’s instructions and local

codes regarding the requirements for passing the exhaust venting system through a combustible

wall or ceiling.
Inspect and Clean Exhaust Venting System Frequently.

Use a 3" or 4" diameter type "L" or "PL" venting system.
Do Not Connect This Unit to a Chimney Flue Serving Another Appliance.

FOR USE WITH WOOD PELLET FUEL OR UP TO 50% CORN / PELLET MIXTURE ONLY.

The Use of Other Fuels May Create an Unsafe Condition.

Input Rating Max: 5.5 lb. fuel/hr.
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPS

Route Power Cord Away From Unit.

DANGER: Risk of Electrical Shock. Disconnect Power Before Servicing Unit.
For Further Instruction, Refer To Owner's Manual.
Replace glass only with 5mm ceramic available from your dealer.
Keep Viewing and Ash Removal Doors Tightly Closed During Operation.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

MINIMUM CLEARANCES TO COMBUSTIBLES/

DISTANCES DE SECURITE PAR RAPPORT AUX

MATERIAUX COMBUSTIBLES:

Back Wall / Entre Mur Arrière   2”/ 51mm 

2”/ 51mm

Side Wall / Entre Paroi Latér 

16”/ 406mm 

10”/ 254mm

CORNER INSTALLATION / EN ANGLE

Walls to Appliance  

9”/228mm 

9”/228mm

Entre Murs et appareil

Flue Connector/Raccord à la cheminée     3” /76mm
FLOOR PROTECTION / Protection Du Plancher

 

     USA Canada

Sides*/Côtés   (A)     6” 

200mm

Back**/Arrière (B)     6” 

200mm

Front*/Avant   (C)     6” 

450mm

**Measured from pedestal base in the US ONLY

**Mesuré à partir de la base du socle aux États-Unis uniquement

*Measured from Glass Opening

*Mesurer à partir de la surface de la porte en verre
Floor Protection Must Be a Non-Combustible Material.

Must  Also  be  Place  Under  Any  Horizontal  Flue  Connector, 

Extending 2” or 51mm Beyond the Pipe Measurement.

Pour protéger le plancher, il faut sous le pêole un matériau. Qui 

doit aussi être placé sous les parties horizontales du tuyau de 

raccord à la cheminée et s’étendre à 51mm o 2 po. au-delà de 

la mesure du tuyau.

Made in U.S.A. of US and imported parts. / Fabriqué

aux États-Unis-d’Amérique par des pièces d’origine

américaine et pièces importées.

"PREVENTION DES INCENDIES"

Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignes

de fonctionnement. Respecter les règles de sécuritè en vigueur dans votre région.

AVERTISSEMENT POUR MOBILE HOMES:

 Ne pas installer dans une chambre. ll est imperatif

de prévoir une prise d'alr extérieur. L'intégrité structurale du plancher, du plafond et des murs doit étre

strictement préservée. Se reporter aux instructions du fabricant et aux réglementations spécifi ques

locales concernant les précautions requises lors de la traversée d'un mur ou d'un plafond.

Contróler et nettoyer fréquemment tout le systeme d'evacuation des fumées conformément aux

recommandations du constructeur. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou

102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà utilisé pour un autre appareil.

FONCTIONNE EXCLUSIVEMENT AVEC DES GRANULES DE BOIS

.

Appareil de chauffage à granulé type. Consommation maximum: 2.5 kg/h.

US coupure: 115 VAC, 60 Hz, 4.2 amps Démarrer, Exécuter 2.8 AMPS

fonctionnement normal 1.1A. Tenir le cordon d'alimentation à l'écart du poèle.

DANGER: Risque d'électrocution. Débrancher l'appareil avant toute intervention.

Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme qualité disponible

auprès de votre revendeur.

Pour une information plus compléte, se reporter à la notice d'utilisation. Tenir la porte

hermétiquement close durant fonctionnement.

Ne faites pas obstacle l’espace sous le réchauffeur. Toujours fournir un approvisionnement suffi sant en air frais 

jusqu’au lieu d’installation Appliance

BARCODE LABEL

Date of Manufacture / Date de fabrication:

P.N. 3-90-04300

WITHOUT

SIDE SHIELDS

WITH

SIDE SHIELDS

Sans Écrans

Latéraux

Avec Écrans

Latéraux

Fabriqué par: Harman Stove Company 352 Mountain House Road, Halifax PA 17032

US ENVIRONMENTAL PROTECTION AGENCY

This model is exempt from EPA certifi cation under 40 CFR 60.531

by defi nition [Wood Heater (A) "Air-to-Fuel Ratio"]

Agence Américaine pour la Protection de l’Environnement

Ce modéle est dispensé par EPA certifi cation d’aprés 40 CFR 60.531

par dèfi nition [Appareil á bois (A) << Ratio air/combustible>>]

2012   2013   2014   jan   Feb   Mar   aPr   MaY   jun   jul   aug   seP   oct   nov   dec

Harman PP38+/P43 Pellet Stove

Label measures: 4-3/8" high X 10-3/4"wide

Black Background with bare metal for print-adhesive backed, metal plate.

008

Serial No.

N

o

 de série:

Report #/ Raport # 135-S-21-6.2 (PP38+)

Report #/ Raport # 135-S-23b-6.2 (P43)

Tested to / Testé à:

ASTM E1509-04, ULC/ORD-C1482-

M1990, ULC-S627-00

Room Heater Pellet Fuel Burning Type. Also for use in Mobile Homes.

Appareil de chauffage à granulés de bois Utilisable dans des mobile homes. 

This pellet burning appliance has been tested and listed for use in Manufactured 

Homes in accordance with OAR 814-23-900 through 814-23-909

MODEL / MODÈLE:      "PP38+ /       P43"

2"(51mm)

10" (254mm) with side shields

16" (406mm) w/out side shields

a

a

c

b

usa

canada

F

loor

 

protector

Protection de sol

Floor Protection

9"(228mm) 

9"(228mm)

3" min

76mm min
3" min

76mm min

rev c

= contains updated information

Summary of Contents for P38plus

Page 1: ...ermine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman HOME HEATING Model s PP38 Freestanding Pellet Stove NOTICE SAVE THESE INSTRUCTION...

Page 2: ...de pr voir une prise d alr ext rieur L int grit structurale du plancher du plafond et des murs doit tre strictement pr serv e Se reporter aux instructions du fabricant et aux r glementations sp ci que...

Page 3: ...tre plac sous les parties horizontales du tuyau de raccord la chemin e et s tendre 51mm o 2 po au del de la mesure du tuyau Made in U S A of US and imported parts Fabriqu aux tats Unis d Am rique par...

Page 4: ...lified service person Periodic cleaning is required throughout the heating season and at the end of each winter for the stove to work efficiently refer to the maintenance section of this manual WARNIN...

Page 5: ...ions along with all local codes regarding installation of this appliance Do NOT use makeshift compromises when installing this appliance serious consequences may result With any hearth appliance insta...

Page 6: ...he first reading check for possible restrictions or the need for outside air see page 10 For more information on the draft test procedure refer to Page 19 Mobile Home Installation When installing this...

Page 7: ...mbly when measured from the horizontal center line of the regulator I The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air supply inlet to...

Page 8: ...an air tight seal in most cases However in some cases a perfect seal is not achieved For this reason and the fact that the unit operates with a positive vent pressure we specify that the joints also...

Page 9: ...s 15 feet If a longer run is needed the size must be increased to 3 Inlet cover part number 1 10 08542 should be used to keep birds rodents etc out of the pipe You may choose to use the optional Direc...

Page 10: ...n wall pass throughs 1 Preferred method This method provides excellent venting for normal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however fo...

Page 11: ...provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in...

Page 12: ...out rain Be sure to use approved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to...

Page 13: ...er installation clearances Minimum flue vent configuration It is required that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of p...

Page 14: ...the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7 Mode Selector Allows you to choose between Room Temp Mode Stove Temp Mode or OFF Also allows you to vary the dis...

Page 15: ...he stove will gradually slow down and hold at the minimum burn rate When the house cools down the stove will automatically bring the room temperature to the precise temperature you desire In the Room...

Page 16: ...er and smoke will escape through window and door gaskets Feed Adjuster Knob For most premium grade pellet fuels the Feed Adjuster Knob should be set at 4 If higher ash fuels are used the setting shoul...

Page 17: ...e burn pot When the stove is ignited these scrapings will be pushed out by the feeder and burned 6 The ash pan can hold the ashes from approximately 1 ton of premium fuel This means the ashes will onl...

Page 18: ...onds to pass for the combustion motor to slow before checking the low draft 6 If the low draft is between 25 and 35 record the reading _____ in W C If the reading is lower check for resistance in the...

Page 19: ...leaned Clean the glass with a soft cloth and mild glass cleaner Do not clean the glass when hot and avoid the use of abrasive cleaners Glass replacement Carefully remove all remaining glass and gasket...

Page 20: ...sed they should be retained in the closed container until all cinders have been thoroughly cooled Other waste shall not be placed in this container Cleaning It is recommended that the stove is cold an...

Page 21: ...THE STOVE LIVE PELLETS IF SUCKED INTO THE VACUUM WILL LIGHT THE VACUUM ON FIRE AND MAY ULTIMATELY CAUSE A HOUSE FIRE 9 Use a brush to clean the flue being careful not to damage the ESP probe see Fig 3...

Page 22: ...e of the burn pot Fig 34 3 Lift off the clean out cover Fig 35 to open the bottom clean out chamber Fig 36 4 Clean ash buildup from inside the chamber while cover is off Use the scraper to tap on the...

Page 23: ...in the firebox through a port on the rear of the feeder Poor draft will result in an interruption of power to the feeder motor Poor draft can be caused by blockage in the exhaust excessive build up o...

Page 24: ...tatus blink A 6 blink control board status indication is caused by poor or incomplete combustion The circuit board has the ability to track the combustion through feed settings and ESP temperatures Wh...

Page 25: ...6 13 Specifications 33 1 8 10 28 5 8 Weight 212 lbs Blower 135 cfm Feed Rate approximate 75lb to 5 5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D inc...

Page 26: ...ary to hold the slate in place on the stove There are 4 decorative slate choices See dealer for samples The Brushed Stainless deer cutout pictured below is another option available This cutout reveals...

Page 27: ...t temperature knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the bu...

Page 28: ...content takes energy to dry and tends to cool the appliance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pel...

Page 29: ...1 4 2 3 6 5 9 8 7 WHITE WHITE WHITE WHITE BLUE EMPTY EMPTY PLUGGED BROWN 11 BLACK PART NO 3 90 773869 WHITE 11 PIN PLUG 10 RED GREEN BONDED TO STOVE BODY GREEN WIRE IS GROUND 1 8 3 R U B B E R C O R D...

Page 30: ...of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whiche...

Page 31: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Page 32: ...826 Y 2 Feeder Assembly Pre SN 008080066 Refer to following page 3 Feeder Assembly Post SN 008080066 Refer to following page 4 Flue Tail Pipe 3 00 247237 Y 5 Auger Motor Cover 2 00 773852P Y 6 Auger M...

Page 33: ...08080066 1 10 7738106A 16 Bolt on Hinge Weldment 2 00 06952B 17 Cast Door Frame 4 00 06800P Cast Door w Glass 1 10 06800A 18 Glass Panel 3 40 950133125 Y Glass Clip w hardware Pkg of 4 Pre 00880001 1...

Page 34: ...amper Assembly 1 10 06466W 2 2 Air Intake Weldment 1 10 773843 2 3 Feeder Weldment 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Assembly 1 10 773890 Y 2 6 Feed Cover and Gasket 2...

Page 35: ...6 Y 3 6 UL Feeder Air Intake 1 10 72222 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132 Y 3 9 UL Feeder Pusher Arm 1 10 677187W Y 3 10 Fines Deflector No...

Page 36: ...Y Gasket 3 8 Rope White LD Ash Door or Load Door 30 Ft 1 00 00888 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y Gasket Hopper Lid 1 00 00248 Y Hopper Lid W HInge 1 10 08518 Y Labels Caution Danger...

Page 37: ...37 PP38 Pellet Stove 3 90 08422R33_06 13 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 38: ...ts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth product designed and assembled by the expe...

Reviews: