D. Optional Blower Installation

The optional blower kit #1-00-797032 installs easily to the 

rear of the Oakleaf. 
Hold the blower assembly into place and secure it with the 

two bolts provided. You'll need a 3/8" wrench or socket to 

tighten the bolts.

Notice: when installing the optional blower, the upper rear 

shield must be moved upward to create the air passage.

Loosen  the  eight  screws  to  remove  the  rear  shield.  Raise  the 

shield to the upper set of holes, re-install the shield, and tighten 

the screws.

E. Optional Rear-vent Rear Shield

Whenever  a  rear  vent  configuration  is  used,  the  upper 

rear  heat  shield,  #1-00-797066  must  be  purchased  and 

installed, to accommodate the flue collar. There are eight 

screws that secure the existing shield. You'll need to break 

away  the  tabbed  portion  of  the  lower  shield  flue  cut-out. 

Remove the screws from the top-vent shield and install the 

rear vent shield in it's place. Height adjustment for blower 

use is done the same as with the top-vent shield in place. 

See 

D. Optional Blower Installation

  (above)  for  detailed 

instructions.

F. Optional Bottom Heat Shield

Part  #1-00-797058 

must

  be  purchased  and  installed 

whenever the Oakleaf is installed on a protected combustible 

floor.  The  shield  installs  on  four  bolts  that  are  protruding 

downward from the base of the stove body. Slide the shield 

under the stove from the back, as this is the only way it will 

fit. Lift into place guiding the bolts through the holes in the 

shield and secure with the nuts that are included with the 

shield.

Plug the blower into a properly grounded electrical outlet. 
You  can  turn  the  blower  on  at  any  time  using  the  rocker 

switch on the rear of the blower housing. Setting the switch 

to "AUTO" will keep the blower off until there is a significant 

amount of heat from the stove. In this setting, the blower will 

also shut off when the stove cools. Keep the blower on low 

speed or off during low fires. As you get out of the low burn 

range, the speed can be set wherever desired, or kept off.

ROUTE POwER CORD AwAY FROM THE APPLIANCE. 

DO NOT RUN THE CORD UNDER OR IN FRONT OF 

THE APPLIANCE. 

WARNING

!

Secure blower with one bolt on each end of the mounting plate.

Shown with lower 

shield knockout 

removed.

If not installing the 

optional blower, the 

upper knockout will 

need to be removed.

Summary of Contents for Oakleaf Wood Stove

Page 1: ...r to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirem...

Page 2: ...u fabricant et les codes locaux En l absence de codes locaux l installation doit au minimum tre conforme aux exigences de la norme NFPA 211 aux U Voir dans les recommandations du fabricant et dans les...

Page 3: ...Component Locator 7 D Flue Direction Conversion 7 E Pre Use Checklist 8 4 Dimensions Clearances A Appliance Dimensions 9 B Clearances to Combustibles 10 C Floor Protection 12 5 Chimneys and Venting A...

Page 4: ...y grounded to the frame of the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home C Glass...

Page 5: ...er combustion by products from the stove Even though this stove is designed to be as safe as possible it is important that you install a CO detector This is true for oil gas or coal burning products a...

Page 6: ...needed to replace what the chimney draws away through the appliance B Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the design...

Page 7: ...ching upward through the firebox and the open bypass damper loosen the retainer bolts on each of the flue collar and the cast iron plate With the bolts loosened turn the retainer to allow the piece to...

Page 8: ...m height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The optional air distribution blower has been installed...

Page 9: ...2 665 5mm 27 2 691mm 29 2 742mm Air Intake 10 2 259mm 18 9 480mm 25 6 650mm Centered 27 6 701mm When configured for rear flue Floor to center of flue measures 23 5 597mm NOTICE When using rear flue c...

Page 10: ...ng 16 407 mm F Minimum Vertical 0 0 mm For clearance reduction methods refer to NFPA 211 or Local Codes Pipe clearance may be reduced using double wall or insulated connector pipe provided that you ad...

Page 11: ...n A Unit to Side Wall 17 432 mm B Unit to Back Wall 13 330 mm C Vent Pipe to Side Wall 26 5 673 mm Corner Installation D Shield Corner to Wall 14 356 mm E NFPA 211 specifies clearance of 18 457 mm B A...

Page 12: ...the area under and around the stove must be protected from falling ash and live coals The area under a horizontal run of chimney connector must also be protected extending two 2 inches beyond the meas...

Page 13: ...ce closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described later...

Page 14: ...bove the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exi...

Page 15: ...your plans See Clearances and Floor Protection in this section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your f...

Page 16: ...imney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Chimney Cap Storm Collar Chimney Sections Minimum Air...

Page 17: ...thimble Flue liner with required air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non...

Page 18: ...ll Not Pass Through an Attic or Roof Space Closet or Similar Concealed Space a Floor or Ceiling Flue Liner with Required Air Space Stainless Steel Chimney Connector Must Extend to Flue Liner Minimum 8...

Page 19: ...r approved lining system Follow liner manufacturer s instructions on insulation and support Floor Protection in Accordance with Solid Fuel Appliance Listing Damper Plate Removed or Fastened in Open Po...

Page 20: ...pace a Floor or Ceiling Minimum clearance from chimney connector to uprotected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 c...

Page 21: ...6 Follow the vent manufacturer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 8 The appliance...

Page 22: ...wall portion 6 Slide the other end of the metal intake flex pipe into the stub on the rear of the Oakleaf and secure it with aluminum tape This air intake will supply outside air for the secondary co...

Page 23: ...place See D Optional Blower Installation above for detailed instructions F Optional Bottom Heat Shield Part 1 00 797058 must be purchased and installed whenever the Oakleaf is installed on a protecte...

Page 24: ...to the explanation of draft and its effect on stove performance in the Installation section By following the installation and operating guidelines you will ensure proper draft and gain maximum effici...

Page 25: ...he ash to fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling...

Page 26: ...thepaper and close the loading door s Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making...

Page 27: ...nd damper bypass before taking the ashes outside for safe disposal Avoid overfiring your stove Overfiring is a potentially hazardous situation which can lead to overheating of combustible materials ne...

Page 28: ...your stove is sluggish and you get occasional odor check these possibilities and increase the air flow in your home Seasonal cleaning At least once per year the stove venting connectors and chimney s...

Page 29: ...eplace gasket as needed Do not operate the stove with a broken glass Replacement glass which is ceramic glass should be obtained only through your Harman dealer To replace a broken glass first be sure...

Page 30: ...dust and pet hair from the blower wheel Reinstall the blower and tighten the two bolts securely 5 Chimney Connector Frequency As necessary Yearly By Qualified Service Technician User At the end of the...

Page 31: ...Harman Oakleaf Owner s Manual_R11 2013 ___ 09 13 31 3 90 798 Variable Speed Switch Power Cord Blower Thermostat Rocker Grounded to housing Switch Black Wire White Wire 2 1 Oakleaf Optional Blower Kit...

Page 32: ...ding Manufacturing Date Active Part number list on following page Cast Iron wood Stove 1 90 797000 1 Black Sept 2010 thru June 2011 1 90 797000 2 Charcoal 1 90 797000 3 Goldenfire 1 2 7 6 8 23 22 3 4...

Page 33: ...Ft 1 00 2312 Y 7 Oakleaf Package 3 40 797022 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 8 Ramp Assembly w Gsket 1 10 797109 Y Gasket 1 4 Round PSA 15 FT 1 00 2312 Y 9 Brick Clip Set 1 00 249153 Y 10 Da...

Page 34: ...crew HCS 3 8 16 X 1 Z Pkg of 50 3 30 1134 50 Y Bolt CB 5 16 18 X 2 Z Pkg of 25 3 30 4001 25 Y Nut FHN 5 16 18 Z 5 Pkg of 100 3 30 8005 100 Y 21 Base Plate Qty 2 req 2 00 797027S 22 Center Brick 3 40 7...

Page 35: ...after July 1 1990 0 8 5 Grams Per Hour SMOke 50 60 70 80 90 100 Wood heaters with higher efficiencies cost less to operate effIcIency Heat OutPut 9 600 to 24 700 btu use this to choose the right size...

Page 36: ...tion warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier Th...

Page 37: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Page 38: ...Oakleaf Woodburning Stove Dry Seasoned Wood Only Harman Oakleaf Owner s Manual_R11 2013 ___ 09 13 38 3 90 798 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 39: ......

Page 40: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Reviews: