Oakleaf Woodburning Stove
Dry Seasoned Wood Only!
Harman® • Oakleaf Owner's Manual_R11 • 2013 -___ • 09/13
18
3-90-798
Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection)
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in place
of the existing shield.
The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a
Floor or Ceiling.
Flue Liner with Required Air Space
Stainless Steel Chimney
Connector Must Extend to
Flue Liner
Minimum 8" Masonry
Thickness in Front of
Smoke Chamber
Use Damper Adapter or Seal with
Non-Combustible Material
Airtight
insulated
Clean-Out
Damper Plate is Removed or
Fastened in Open Position
Listed Fireplace Trim Protection
for Reduced Clearance
Floor Protection*
Combustible Floor
*Floor Protection in Accordance with Solid Fuel Appliance Listing