20
MAC Ultra Performance Safety and Installation Manual
3. Click on
Select Folder
. Martin Companion will automatically save the firmware files in a correctly named
folder to the USB drive’s root directory.
4. When you see a
Download Successful
message you can close Martin Companion. Check that the
USB drive now contains a folder whose name is the fixture type and software version. Then use an
Eject
command in Windows to make sure that you can remove the drive safely, and remove the drive from the
PC.
5. Apply power to the fixture and allow it to boot. Insert the USB drive into the USB host socket next to the
fixture’s control panel. The fixture should illuminate the display and the contents of the root directory
should appear in the display. If the fixture does not recognize the USB drive automatically, navigate to
SERVICE
→
USB
in the control panel.
6. Scroll to the folder that contains the update files on the USB drive. Select the folder and press ENTER.
The update will begin automatically and the display will show progress status. At the end of the update
process the fixture will reboot. Do not remove the USB drive until the reboot is complete.
7. Remove the USB drive from the fixture. The newly-installed firmware version will now be displayed in the
INFORMATION
menu.
Opening the head for access
To open the head for access to the rotating gobos:
1. Disconnect the fixture from power and allow to cool for 30 minutes.
2. Place the fixture on a suitable work surface.
3. See Figure 12. Position the fixture so that the Martin logo on the back of the head is the right way up.
The top and bottom head covers are now on the top and bottom of the head respectively. Apply the tilt
lock
A
.
4. Remove the two retaining screws
B
from the top head cover, slide the cover towards the front of the
fixture to release the back of the cover, and lift the cover away from the head slightly. Press the retaining
clip
C
on the cover’s safety wire in towards the head chassis, slide the clip along its slot until you can
remove it, and then remove the safety wire and head cover completely from the fixture.
5. Release the tilt lock, reposition the head and remove the bottom head cover in the same way.
When closing the head, follow the above procedure in reverse. Check that the head covers are held
securely after you have reinstalled them, and release the tilt lock before reapplying power or packing the
MAC Ultra Performance in its flightcase.
Figure 12: Removing the head covers