28
Martin PDE Junction Box / Break-In / Break-Out Cable user guide
Typical half-cycle RMS inrush current at 230 V, 50 Hz .................................................... 1.5 A
Typical earth-leakage current ...................................................................................... 0.25 mA
Typical Power and current
100 V, 60 Hz ....................................................................................... 5.1 W, 0.089 A, PF 0.58
120 V, 60 Hz ....................................................................................... 5.1 W, 0.078 A, PF 0.56
208 V, 60 Hz ....................................................................................... 5.5 W, 0.048 A, PF 0.55
230 V, 50 Hz ...................................................................................... 5.7 W, 0.046 A, PF 0.55
240 V, 50 Hz ....................................................................................... 5.9 W, 0.046 A, PF 0.55
Measurements made at nominal voltage. Allow for a deviation of +/- 10%.
PF = power factor.
Thermal
Cooling .................................................................................................................... Convection
Maximum Ambient Temperature (Ta max) ........................................................................ 40 C
Minimum Ambient Temperature (Ta min) ............................................................................ 0 C
Typical Heat Dissipation (calculated, +/- 10%) ......................................................... 20 BTU/hr
Approvals
Global CB Certification/IECEE......................................................................... IEC 61347-2-11
EU Safety ........................................................................................ EN 61347-2-11, EN 62493
EU EMC ...............EN 55015,EN 55032,EN 55103-2,EN 61000-3-2,EN 61000-3-3,EN 61547
US Safety ...................................................................................................................... UL1573
US EMC ....................................................................................................47 CRF §15 Class B
Canadian Safety .......................................................................................... CSA 22.2 No. 166
Canadian EMC.............................................................. ICES-003 Class B, ICES-005 Class B
Australia/NZ ...................................................................................................................... RCM
United Kingdom............................................................................................................... UKCA
Passive Junction Box Power-DMX-Ethernet to PDE
Physical
Length .......................................................................107 mm (4.2 in.) (incl. mounting flanges)
Width .................................................................................................................. 94mm (3.7 in.)
Height................................................................................................................. 51mm (2.0 in.)
Weight ................................................................................................................ 0.5 kg (1.1 lb.)
Construction
Color..................................................................................................................................Black
Housing Material .......................................................................................................Aluminium
Protection Rating .............................................................................................................. IP 65
RoHS......................................................................................................................... Compliant
REACH...................................................................................................................... Compliant
Installation
Orientation........................................................................................................................... Any
Wallmount ............................................................................................Using mounting flanges
Trussmount ............. Using half-coupler clamp in M10 threaded hole, max. bolt length 22 mm
Location..................................................................................indoor or temporary outdoor use
Connections
AC Power input .......................................................... Neutrik powerCON TRUE1 TOP (IP 65)
DMX input ........................................................................Neutrik XLR 5-pin Male TOP (IP 65)
Ethernet input........................................................................... Neutrik etherCON TOP (IP 65)
AC Power, DMX and Network out.............................................. PDE hybrid connector (IP 65)
All connections hot plugging compatible
Electrical
AC power ...............................................................................100-240 V AC nominal, 50/60Hz