Using the VC-Grid
21
VC-Grid CW, MW and WW
LEDs
Output
Indication
Action required
LEDs 1
and 3
Constant
Busy (e.g. booting up or writing to
flash memory).
Wait a moment for normal operation
to be resumed.
LED 1
Constant
Error. The VC-Grid has encountered
a fatal error and can not run.
Perform a factory reboot, followed by
a firmware upload.
LED 1
Flashing
No control source detected.
Connect a P3 system controller or
DMX source to the network.
LEDs 1
and 2
Flashing
Ready. VC-Grid connected to P3
controller but not receiving valid P3
data stream.
Set up the P3 controller to use the
VC-Grid.
LEDs 1
and 2
Constant
Running normally in P3 mode.
None.
LEDs 1, 2
and 3
Flashing
Ready. VC-Grid connected to DMX
controller but not receiving valid
DMX data stream.
Set up the DMX controller to use the
VC-Grid.
LEDs 1, 2
and 3
Constant
Running normally in DMX mode.
None.
Table 3: White models status information