Front panel 

Input/Output channel monitoring 

Each channel has the following LED indicators: 

 

 

 

 

 

 

Clip 

Indicates clipping in the analogue domain for each input or output channel. The LED will 

illuminate at +18.5dB.

Signal

 

The Signal LED will illuminate for each input or output channel when the signal reaches 

or exceeds the signal threshold of -20dB.
Input channels have a third indicator:

48V 

(Input channels only) Illuminates to in48V phantom power has been activated for 

the relevant input channel.

Other indicators

  

COM (Communications)

 

The COM LED turns green to indicate a normal linked condition.  The COM LED blinks 

green if data is being transferred on the Ethernet or RS232 port.  The LED turns yellow if a 

link is established but no IP address has been established.

STAT (Status)

 

The STAT LED turns green when a valid design file is loaded and running.  The STAT 

LED turns yellow when the design is paused.  The STAT LED turns red when the design is 

stopped.

ERR (Error)

 

The ERR LED is normally off.  It turns red in the case of a critical or fatal error.

PWR (Power)

 

The PWR LED turns blue when the device is powered on.  It blinks during locate 

operations (both when pressing the locate button on the rear of the device and also when 

locating the device from within the software).

Summary of Contents for BSS Soundweb London BLU-101

Page 1: ...1 Soundweb TM London BLU 101 Installation Guide 5033747 B...

Page 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...

Page 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...

Page 4: ...STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops...

Page 5: ...The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no...

Page 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...

Page 7: ...ded by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for th...

Page 8: ...Qnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL...

Page 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...

Page 10: ...to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 12 c...

Page 11: ...Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weigh...