background image

11

CONTROL PORTS:

  

12 inputs and 6 outputs 

Control Input Voltage:

  

0 to 4.5v 

Control Input Impedance:

  

4.7kOhms to +5V (2-wire mode) >1MOhm (3-wire mode) 

Logic Output Voltage:  

0 or +5V unloaded 

Logic Output Impedance:

  

440 Ohm 

Logic Output Current:  

10mA source, 60mA sink

WATCHDOG OUTPUT:

  

Phoenix/Combicon connector for failsafe control 

Opto Output current:

  

14mA maximum

Withstanding voltage:

  

80V maximum (Off) 

Series Impedance:

  

220 Ohms (isolated) 

CONTROL NETWORK

Connectors:

  

RJ45 Ethernet connector 

Maximum cable length:

  

100m/300ft on Category 5 cable between device and Ethernet switch 

Maximum number of nodes:

  

60

BLU-link

TM

 AUDIO NETWORK

Connectors:  

2 x RJ45 Ethernet connectors

Maximum cable length:

  

100m/300ft on Category 5e cable between devices

Latency:

  

11/Fs [0.23ms@48k]

Pass Through Latency:

  

4/Fs [0.08ms@48k]

POWER AND DIMENSIONS

Mains Voltage:

  

100-240V AC, 50/60Hz 

Power Consumption:

  

<55VA

BTU Rating:

  

<188 BTU/hr

Operating Temperature Range:

  

5(41) to 35(95) degrees C(degrees F)

Dimensions (HxWxD):  

1.75” (45mm)(1U) x 19” (483mm) x 12.5” (318mm)

Weight:  

9.1 lbs / 4.1 kg

BSS Audio incorporates high quality mechanical fans in some products. All mechanical fans have a limited life 

expectancy. We recommend annual inspection of fans for dust occlusion and excessive noise. Fan assemblies should 

be replaced after six to ten years of use. Environmental factors such as elevated temperature, dust, and smoke can 

adversely affect fan life. Systems exposed to these conditions should be inspected more frequently. Fan replacement can 

be performed either at the factory or by an experienced technician in the field. Please contact BSS Technical Support for 

more information on purchasing replacement parts or product service. 
BSS Audio has a policy of continued product improvement and accordingly reserves the right to change features and 

specifications without prior notice.

Summary of Contents for BSS Soundweb London BLU-101

Page 1: ...1 Soundweb TM London BLU 101 Installation Guide 5033747 B...

Page 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...

Page 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...

Page 4: ...STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops...

Page 5: ...The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no...

Page 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...

Page 7: ...ded by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for th...

Page 8: ...Qnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL...

Page 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...

Page 10: ...to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 12 c...

Page 11: ...Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weigh...

Page 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in Malaysia...

Reviews: