background image

AXYS

®

 Intellivox ADC Installation Manual

11

201509/ADCIM

This manual describes the recommended installation 
procedure for the AXYS

®

 ADC range of loudspeakers. 

The ADC range are compact 100 V/70 V line units intended 
for use in a wide variety of Public Address and Voice 
Alarm (PA/VA) systems. They are particularly suitable for 
installation in reverberant spaces such as railway and bus 
stations, airports, places of worship, shopping centres, etc., 
where high quality speech reproduction is required. 

The AXYS

®

 Intellivox ADC device is a loudspeaker type 

known as passive loudspeaker array, in which multiple 
drive units are mounted in the housing at specific spacings. 
In addition to the drivers, the Intellivox ADC housing 
contains a set of passive filters. When properly applied, the 
Intellivox ADC device is capable of achieving a constant 
SPL for mid-band frequencies over the listening area, 
whilst minimizing the ‘spill’ to other areas.

other key features include:

 

• Pilot tone indication

 

•   Protection (glass + thermal fuse and ceramic  

terminal block)

 

• EQ correction and high-pass filter

This manual covers:

 

• Wiring and connection details 

 

• Mechanical installation of the loudspeaker

 Please note that a full range of optional mounting brackets 

and connection coverboxes are available. Please 
refer to our website for further details.

APPlIcABlE moDElS, AND VArIANTS

The Intellivox ADC range is available in two versions: 

•   Model V90  – for vertical mounting 

(Part Nos. 576125, 577125 and 577135)

•   Model H90 – for horizontal mounting 

(Part Nos. 576126, 577126 and 577136)

This manual is applicable to both models. However, some 
factors arising from the two models’ different physical 
configurations result in some sections of the manual text 
being strictly applicable to only the V90 or the H90. These 
sections are clearly indicated. 

Apart from the passive filters, the two models are both 
electrically identical and can use the same mounting 
brackets. However their effective areas of coverage are 
very different, and the decision as to which is specified in 
a particular installation will be dictated by the specifics of 
the building or space. 

2. INTroDUcTIoN

fig.1.1 Model V90 – for vertical mounting 

fig.1.2 Model H90 – for horizontal mounting

Summary of Contents for AXYS TUNNEL Intellivox ADC-V90

Page 1: ...Installation Manual Intellivox ADC V90 ADC H90 models Part Nos 576125 577125 577135 576126 577126 and 577136 EN54 24...

Page 2: ...oudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings Product model type ADC V90 ADC H90 Document references Datasheet s 201509 V90_2 3 ADC V90 datasheet 201509 H9...

Page 3: ...with the applicable harmonised technical specification as foreseen by the manufacturer Construction product Loudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings...

Page 4: ...1 7 Declaration of performance concerning a construction product covered by a harmonised standard Notified body details Name Scientific and Research Centre for Fire Protection named after J zef Tulisz...

Page 5: ...Section 4 4 Marking and data Passed Section 4 5 Rated noise power durability Passed Section 5 6 Enclosure protection Passed Section 5 18 Dry heat operational Passed Section 5 7 Dry heat endurance Pass...

Page 6: ...in conformity with the declared performance in point 9 This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4 Signed for and on behalf of the...

Page 7: ...mes mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has been...

Page 8: ...AXYS Intellivox ADC Installation Manual 8 201509 ADCIM This page has been left blank intentionally...

Page 9: ...riants 11 What s in the packaging 12 3 Installation Guide 13 Preparing For Installation 13 Intellivox ADC Connections 13 Mechanical Installation 14 Acoustic Centre 14 Mounting Options 15 16 Mounting P...

Page 10: ...ators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod bracket or...

Page 11: ...mal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full range of opti...

Page 12: ...ument ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan head s...

Page 13: ...plane This restriction does not apply to the Model H90 which is intended to be tilted downwards Intellivox ADC connections The Intellivox ADC range loudspeakers are designed to be connected to 100 V o...

Page 14: ...see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the loudspeake...

Page 15: ...ting angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B MOUNTING OPTIO...

Page 16: ...he third method is to mount the column within a recess in the wall or dedicated mounting panel so that the f r o n t of the unit is flush This is a specialised mounting situation which will be encount...

Page 17: ...or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver access t...

Page 18: ...tion the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme Tap Setting The...

Page 19: ...frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are valid for the...

Page 20: ...nes of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly Speaker Protection In...

Page 21: ...Intellivox hinge bracket 90 RAL 9007 802005 Intellivox swivel bracket 90 RAL 9007 806668 Intellivox swivel bracket 45 RAL 9007 806678 Intellivox wall bracket set 2 pcs 25 mm RAL 9010 802225 Intellivox...

Page 22: ...AXYS Intellivox ADC Installation Manual 22 201509 ADCIM This page has been left blank intentionally...

Page 23: ...AXYS Intellivox ADC Installation Manual 23 201509 ADCIM This page has been left blank intentionally...

Page 24: ...DURAN AUDIO BV Koxkampseweg 10 5301 KK Zaltbommel The Netherlands tel 31 418 515583 fax 31 418 518077 http www duran audio com Info duran audio com...

Reviews: