Encoder Configuration Options
45
N3000 Series User Manual
EDID Page
Click the
EDID
link at the top of any of the main web pages to access the page shown in
. Every display has stored
information that it communicates to the output device. This page allows you to view that information.Options are described in
. Edit the Encoder’s EDID if you need to change the display options available to the source. There are four different ways to
control the EDID of the Encoders:
Option 1:
Use the default settings drop-down menu and select from the options available. Then click
Set EDID
. This will work for
most sources and is most often set to
Stereo (2 channel)
.
Option 2:
When using an EDID captured from a display connected to a Decoder, paste the data in to the white EDID block,
overwriting existing EDID. Then click
Set EDID
.
Option 3:
Make changes to the operating parameters displayed on the right side of the screen. Use the
Encode
button to translate
the changes into a new EDID and click
Set EDID
.
Option 4:
Connect a compatible display to the Encoder's
HDMI OUT
or
DVI-D OUTPUT
port and click
Set EDID to Pass-thru
.
The source will need to be disconnected while modifying EDID settings.
FIG. 37
EDID Page
TABLE 15
EDID Page Options
Option
Description
EDID drop-down box
Select what EDID information to display.
Pass-thru:
Displays EDID information for the display connected to the Encoder’s pass thru port.
Local (Digital/Analog)
: Displays EDID information for the Encoder. This information is being provided to the
source connected to the Encoder.
Decode button
Click to translate the EDID currently displayed on the left to the operating parameters listed on the right.
Encode button
After making any changes to the operating parameters listed on the right, click this button to update the EDID
information on the left. To store the new settings, click
Set EDID
.
Read EDID
Click to initially show the EDID or to refresh the EDID table if the source EDID has changed.
Set EDID
If creating a custom EDID, click to apply the changes.
Set EDID to Pass-thru
Set the EDID to the pass-thru EDID of the connected display to the
HDMI OUT
or
DVI-D OUTPUT
port.
Reset EDID
For
Digital
, choose a standard EDID from the drop-down menu and click
Reset EDID
to apply. For
Analog
, no
selection is necessary.