Network Communication via DHCP

1.  In the 

Ethernet page, press DHCP/Static field to open the DHCP/Static 

window. Note that 

DHCP is the default setting.

2.  Select 

Host Name, enter the new host name

3.  Press 

OK to save changes.

Network Communication via Static Address

1.  In the 

Ethernet page, press DHCP/Static to open the DHCP/Static window.

2.  Select 

Static to open the Static IP window.

3.  Press any field to open a keypad or keyboard (depending on the field), and 

enter the appropriate network address information.

4.  Press 

OK to save your changes and return to the Ethernet page.

Connecting to a NetLinx Master

To establish the type of connection to make between the panel and the 

NetLinx Master: 

1.  In the 

NetLinx page, press Mode to choose the connection mode (URL, 

Listen or Auto):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION MODES

Mode

Description

Procedures

URL

The device connects to the target 
Master’s IP address via a TCP 
connection.

1.  Select 

URL in the Mode menu.

2.  Enter the 

Master IP/URL, Master Port Number, and 

Username/Password (if required by the Master).

3.  Press 

OK to save changes.

Listen

This mode allows the panel 
to“listen” for the Master’s 
communication signals.
Note that in this mode, the 

System 

Number and Master IP/URL fields 

are read-only.

1.  Select 

Listen in the Mode menu.

2.  Confirm the panel’s IP address is on the Master’s 

URL list (via NetLinx Studio).

3.  Press 

OK to save changes.

Note: The Host Name (set on the Ethernet page), can 

be used to locate the panel on the Master (

particularly 

useful for DHCP connections where the IP address  

can change).

Auto

Use this mode when both the 
panel and the NetLinx Master are 
on the same Subnet.

1. 

Sele

ct 

Auto in the Mode menu.

2.  Enter the System Number and Username and 

Password (if applicable).

3.  Press 

OK to sav

e changes.

2.  If password security is enabled on the target Master, enter the Username 

and Password:

a. Select 

Username to open the NetLinx window.

b. Enter the 

Username and Password required by the Master.

c. Press 

OK to save changes and return to the NetLinx page.

Related Software and Additional Documentation 

(at www.

amx.com)

•  Programming the Modero G5 touch panel requires the use of either Rapid 

Project Maker (RPM) or the latest version of Netlinx Studio and TPDesign5, 
both available to download at www.amx.com. Refer to the NetLinx Studio 
and TPDesign5 online help for information.

•  For information on designing touch panel pages intended to optimize the 

Modero G5 experience, refer to the G5 Considerations Guide.

•  For additional information on the MT-702 panel, refer to the 

Modero G5 

Touch Panel Instruction Manual.

•  For detailed information on the Settings menu as well programming 

information and instructions on upgrading firmware, refer to the 

Modero G5 

Programming Guide.

•  Detailed specifications drawings for the MT-702 are available to download 

from www.amx.com.

 

© 2018 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are 

registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks 

of their respective companies. AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications 

without prior notice at any time. The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153

AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/

LAST REVISED: 10/09/2018  