12
The room sensor is a small temperature sensor
on the end of a 60" gray or black wire. This sensor
is installed much like a standard wall thermostat.
Because it is so small, it can be hidden along the
trim of a doorway or even up the leg of a coffee
table. There is a remote room sensor port on
the rear of the unit for easy external connection.
Use standard 18-2 thermostat wire to extend the
distance to the desired location (50' maximum).
The room sensor should be installed in the location
where you want to control the temperature.
NOTE:
distances of more than 25 feet from the
unit or in another room are not recommended. It is
recommended that the room sensor be installed,
even if only installed on the rear of the unit as a
return air sensor. The room sensor is essential for
the Advance's excellent efficiency.
Air grill Installation
do not allow pellets or sawdust to build up on the
hopper lid gasket.
Inspect the hopper lid gasket for damage. A
good hopper lid seal is very important for proper
operation.
Insert the two tail end hooks of the Air grill
Assembly up under the stove top edge. Insert
inward until the two center hooks drop into the
stove body slots in the front of the unit.
Fig. 16
Fig. 17
room Sensor and Air grill Installation
room Sensor Installation
rEmINdErS
Fig. 18
Hopper Lid
Foam Gaskets