Harman® • Accentra52i-TC Installation Manual_R8 • 2017 -___ • 01/19
9
3-90-00584i
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 3.2).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY. Illustrations/diagrams are not
drawn to scale. Actual installation may vary due to individual
design preference.
B. Clearances to Combustibles & Floor Protection
* Floor protection must be used from hearth opening to 6" (152mm) in front of door glass and 6" (152mm) to each side
of the stove body OR 8” (203mm) to sides to protect combustibles from hot ashes. A minimum size will be 16.5" deep
by 30" wide and be made of a non-combustible material or meet UL approval.
Figure 3.2
A
= to sidewall
B
= to 12" mantel
C
= to 3/4" trim
D
= to 3/4" trim
E
= floor protection
12” (305mm) Mantel
B
A
E
E
C
D
Clearances:
A
B
*C
*D
E
(From Glass)
From Insert Body:
12” (305 mm)
12” (305 mm)
0”
0”
6” (152 mm)
*3/4 Trim, Zero Clearance to Cast Surround
G
H
F
Location
Inches
Millimeters
F
Minimum Width
24-7/8
632
G
Minimum Depth
15-9/16
395
H
Minimum Height #1-90-574240
24
610
H
Minimum Height #1-90-574220
22
779
H
Minimum Height #1-90-574200
20
508
C. Minimum Opening - Masonry and Manufactured Fireplaces