B. Loss of Power

Harman  pellet  burning  appliances  rely  on  a  combustion 

blower to remove exhaust from the firebox. A power failure 

will  cause  the  combustion  blower  to  stop  running,  which 

may lead to exhaust see page into the room. Vertical rise in 

the venting system can help create natural draft, which may 

reduce the likelihood of exhaust leakage into the home.

Installation of a low-cost uninterruptible power supply (UPS) 

or battery backup system can help ensure the units shuts 

down without any minor smoke leakage into the home. 

Harman recommends the installation of one of these two 

systems for areas prone to power outages.

There is one Harman® approved UPS option for your 

appliance:

Uninterruptible Power Supply UPS

 battery back-ups are 

available online or at computer and office equipment stores. 

Your Harman® appliance with Rev E or later software 

available  beginning  in  November  2010  may  be  plugged 

directly into a Harman® approved UPS:

• 

TrippLite model INTERNET750U

 is tested and 

approved.  Other  brands  or  models  may  not  be 

compatible.

When power is lost, a fully charged UPS will power a safe, 

combustion  blower  only  shut-down.  Your  appliance  will 

pulse the blower every few seconds to clear exhaust until 

the fire is out.

 NOTE: The UPS provides safe shut-down 

only. It is not intended for continued operation.

•  A Inverter/Charger connects to a 12 volt deep cycle 

battery  that  will  run  your  appliance  for  up  to  eight  (8) 

hours. It includes a trickle charge feature that keeps your 

battery charged when power is available. 

NOTE:

 If the 

power is out for longer than battery life, smoke leakage 

may still occur unless your stove has been safely shut 

down.

For an approved Inverter/Charger refer to www.

harmanstoves.com.

Your appliance will recognize when power is restored. What 

happens depends on ESP temperature and whether it is 

equipped with automatic ignition:

 

In “Automatic” Mode

, units equipped with automatic 

ignition will respond to the set point and ESP temperature 

and resume normal operation.

• 

In “Idle” Mode

, or for units without automatic ignition:

•  If the ESP is cool, the appliance will remain shut 

down.

•  If the fire is out and the ESP is still warm, the feeder 

may restart. Since the fire is out, the ESP temperature 

will not rise. The unit will then shut-down, and may 

flash a six-blink status error. (See ESP error codes)

•  If  the  fire  is  still  burning,  it  will  resume  normal 

operation.

Contact  your  dealer  if  you  have  questions  about  UPS 

compatibility with your appliance.

IMPORTANT! :

 UPS or Battery Backup cannot prevent smoke 

leakage from an improperly maintained unit. Keep the venting 

system  clean  and  free  from  obstructions  and  maintain  all 

gaskets to keep an airtight seal.

Use only Harman

®

 approved battery back-up devices. 

Other products may not operate properly, can create 

unsafe conditions or damage your appliance.

CAUTION

!

Always keep appliance doors and hopper lid closed 

and latched during operation and during power 

failures to minimize risk of smoke or burn-back.

D. Emergency Manual Ignition

Harman

®

 pellet stoves and inserts should be lit using the 

automatic ignition system. This is the safest and most 

reliable way for igniting the unit.  In the event the automatic 

igniter is not functioning, the steps below may be followed 

to manually light the stove or insert in the “Constant Burn” 

mode. Manual lighting is for emergency purposes only, 

and the igniter should be repaired or replaced as soon as 

practical.

WARNING

!

Only  use  firestarter  commercially  marketed  for  pellet 

stoves  and  inserts,  including  wax  coated  wood  chips, 

pellet  starter  gel  and  pellet  igniter  blocks.  Use  of  any 

other type of firestarter is prohibited.

To  avoid  serious  injury  or  death  read  and  follow 

manufacturer’s warning and instructions for use of firestarter. 

Use of firestarter is only permitted when performing a cold 

start.
Never attempt to manually light a stove or insert that has 

been  operated  recently  and  is  not  at  room  temperature. 

If  automatic  ignition  was  attempted,  be  sure  to  give  the 

stove or insert at least 30 minutes or longer to cool to room 

temperature.

Be sure that the stove or insert is in the “Igniter - Disabled” 

mode of operation.

Once  all  the  precautions  have  been  taken,  follow  these 

steps:

1.  On  the  touch  control,  select  the  Burn  Mode  icon  then 

select “Constant Burn”.

2.  Arrow back and select the Igniter icon then select “Manual” 

for the ignition method. Select the Home Icon to go back 

to the Main Menu.

3.  Fill burn pot with pellets, only half way. (Do Not Over Fill).

4.  Add  firestarter  to  pellets  following  manufacturer’s 

instructions.

5.  Light pellet firestarter with a match, and close the door, 

touch the On/Off icon on the home screen. Operation will 

begin when the fire reaches the proper temperature.

WARNING

!

Summary of Contents for Absolute43-C

Page 1: ...n WARNING Please read this entire manual before installation and use of this pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even...

Page 2: ...rther instruction refer to owner s manual Keep viewing and ash removal doors tightly closed during operation DANGER Risque d lectrocution Coupez l alimentation lectrique avant l entretien Remplacer le...

Page 3: ...ime Warranty 21 C Loss of Power 23 D Emergency Manual Ignition 23 E Troubleshooting 24 F Contact Information 26 1 Product Specifications and Important Safety Information A Appliance Certification 4 B...

Page 4: ...ons in this manual This wood heater needs periodic inspection and repair for proper operation It is against federal regulations to operate this wood heater in a manner inconsistent with operating inst...

Page 5: ...erative that control compartments and circulating air passageways of this stove be kept clean A Appliance Safety WARNING THIS WOOD HEATER HASAMANUFACTURER SET MINIMUM LOW BURN RATE THAT MUST NOT BE AL...

Page 6: ...d periodically throughout the heating season to determine if creosote buildup has occurred If a significant layer of creosote has accumulated 1 8 or more it should be removed to reduce the risk of a c...

Page 7: ...ure will rob BTU s and may not burn properly Fuel should not be stored within the stove installation clearances or within the space required for cleaning and ash removal Fuel and Fuel Storage Pellet f...

Page 8: ...ill hopper with pellets Initial start up Only 1 Select Language 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations Please Note...

Page 9: ...ency heating needs G Frequently Asked Questions With proper installation operation and maintenance your appliance will provide years of trouble free service If you do experience a problem this trouble...

Page 10: ...er If you did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue...

Page 11: ...E THE STOVE MUSTBE COMPLETELYOUTBEFORE YOU VACUUM THE STOVE LIVE PELLET EMBERS IF SUCKED INTO THE VACUUM WILL LIGHT THE VACUUM ON FIRE AND MAY ULTIMATELY CAUSE A HOUSE FIRE Follow the detailed instruc...

Page 12: ...ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugg...

Page 13: ...nger Cleaning the Heat Exchanger Clean the heat exchanger with scraper as shown in Figure 2 2 Brush or scrape the inside of the stove to remove fly ash Remove the ash pan and dispose of ashes in an ap...

Page 14: ...e bolts Cleaning Igniter Bracket Check cleanliness of the igniter and inner burnpot If the igniter has ash buildup it must be removed to insure proper ignition Use the provided brush to remove ash bui...

Page 15: ...stances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your...

Page 16: ...et Stove 05 20 1 90 777100 1 Black Beginning Manufacturing Date July 2018 Ending Manufacturing Date Feb 2020 1 90 777100 14 Majolica Brown Beginning Manufacturing Date July 2018 Ending Manufacturing D...

Page 17: ...of 100 3 31 94807 100 5 Hopper Lid Hinge w Hardware 1 00 777147 Y Hopper Lid Hinge Pin Plates w Hardware 1 Set 1 00 777560 6 Cast Top Black 4 00 247236S Majolica Brown 1 00 247236 14 7 Hopper Assembl...

Page 18: ...777149 Y Rollers Hardware 1 Set 1 00 77723 Y 16 Ash Pan 1 10 777121A Y 17 Burn Pot Assembly 17 1 Burn Pot Weldment 1 10 777901A Y Gasket Burn Pot 3 44 237639 Y Flame Guide 3 00 03000 Y 17 2 Ingiter 3...

Page 19: ...2 req SRV3 21 07775 Y 28 Rear Cover Right 1 00 777124 Y 29 Differential Switch 3 20 6866 Y Tubing 1 8 Silicone 5 Feet 1 00 5113574 Y 30 Rear Cover Left 1 00 777123 Y 31 Feeder Assembly 31 1 Feeder Bod...

Page 20: ...en requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 5A Ceramic Fuse Pkg of 5 1 00 05237 Y Communication Cable 3 20 72662 Y Draft Meter As...

Page 21: ...er However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor...

Page 22: ...er handling 4 improper operation abuse misuse continued operation with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental conditions inadequate...

Page 23: ...ill not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Contact your dealer if you have questi...

Page 24: ...has failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell...

Page 25: ...Harman Absolute43 C Owner s Manual_R9 2018 ___ 06 20 25 3 90 00772C...