SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  FAIlurE 

TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.

FOr uSE IN ThE u.S. ANd CANAdA.  NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES

IF ThIS APPlIANCE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT.  FOr YOur SAFETY, FOllOw 

INSTAllATION dIrECTIONS.  

CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION 

rEQuIrEmENTS IN YOur ArEA.

CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE 

PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.

CETTE guIdE d'uTIlISATION EST dISPONIblE EN FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hArmAN 

hOmE hEATINg.

SAvE ThESE INSTruCTIONS.

The harman 300i woodburning Fireplace Insert

Installation & Operating manual

R2

“Ce manuel est disponible en Français sur demande”

#3-90-300101

Summary of Contents for 300i

Page 1: ... INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating save these in...

Page 2: ......

Page 3: ...claims any responsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation of substitute materials or replacement parts not approved by Hearth Home Technologies Operating appliance without fully assembling all components Do NOT Overf...

Page 4: ...RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Weight 526 lbs Flue Size 6 inch Log Length Recommended 20 Maximum Heating Capacity 1500 to 3000 sq ft Average Emissions 1 1 Grams Per Hr Emissions on Low 0 08 Grams Per Hr Blower Size 2 120 cfm each NOT FOR USE IN MOBILE HOMES 41 1042mm 40 1016mm 28 711mm 17 6 447mm 12 5 318mm 28 5 724mm 5 1 129mm 17 6 447mm 30 762mm 23 75 603mm He...

Page 5: ...au passage d une cheminée à travers un mur ou un plafond combustible Le tuyau de raccord à la cheminée doit être d un diamètre de 15 25 cm 6 po au minimum en acier bleu 24 MSG La cheminée doit être en métal 103HT d usine ou construite en maçonnerie NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR UN AUTRE APPAREIL IL NE FAUT UTILISER QUE DU BOIS EN BUCHES Ne chauffez pas TROP Si l appareil ou l...

Page 6: ...dle upward and pull open to close the door push the door closed and press down on the handle to latch The door must be closed while the insert is in normal operation and the gaskets routinely examined for wear and replaced when necessary Good door seals are important for maintaining control of the insert Operating the insert with the door inadequately sealed could create a serious over firing cond...

Page 7: ... between the glass and the wood This concept helps to keep the glass clean while providing the oxygen needed to sustain burning This is what is known as Primary Combustion Additional air enters at the bottom rear of the stove body Some of this air enters through holes in the rear bricks where it invigorates the fire at the rear of the firebox The remaining air is delivered into the Firedome combus...

Page 8: ... cannot achieve a charcoal bed within the first 15 to 20 minutes your wood is likely too wet and you may need to burn the fire longer and or hotter to compensate for the extra energy needed to drive out the moisture If after five minutes of burning with the damper closed smoke is visible coming from the chimney you probably do not have the proper coal bed Open the bypass damper and continue with t...

Page 9: ...fessionally cleaned and inspected before resuming burning in your insert Always remember to open the bypass damper when you are loading this allows the exhaust gases to pass directly into the flue outlet and reduces the chance of smoke spillage into the room Reloading Once you have prepared and maintained a thick charcoal bed and the secondary combustion is established you should be able to reload...

Page 10: ...n the glass while it is hot and do not use abrasive substances Wash the surface with cool water and rinse thoroughly You may wish to use a nonabrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your insert Glass Replacement The viewing glass is a specially designed 5 mm ceramic material If the insert s glass is cracked or bro ken you must repl...

Page 11: ...heck the interior of the chimney connector and the chimney itself If creosote has accumulated 3mm or more it should be removed to reduce the risk of a chimney fire To clean deposits from the surface of the connector open the bypass damper to prevent debris from falling into the FireDome and clean using the appropriate brush When cleaning the stainless steel connector it is recommended to use a non...

Page 12: ...e opening to support the insert body Depending on the overall depth of the hearth additional floor protection may be necessary If the depth of the hearth measures 25 5 inches 648 mm or more from the fireplace facing no additional floor protection is needed If the hearth depth is less than 25 5 inches 648 mm floor protection must be installed Floor protection in front of the raised hearth must be a...

Page 13: ...ly 1 4 inch and the roller will disengage when you lower the body It is up to you if you want to raise the roller and lock it in to the disengaged position Lower Base Cover Front Roller Leveling bolt Locked position Ready position Roller Floor Protector Protecteur De Sol Floor protection must ex tend under the insert Never block the air inlets at the front of the insert base 18 457mm 18 457mm 25 5...

Page 14: ...ng the support brackets on each end of the top panel as shown Notice the bottom hole is the one that is threaded Next install the top panel by inserting the four 4 studs through the holes in the fin on the insert Secure with the provided nuts and a 11 32 nut driver Place the top cap down onto the top aligning the two 2 studs with the holes in the top panel Secure from underneath with two 2 nuts In...

Page 15: ...remove the knockout from the surround panel and insert the power cord connectors through it Pull the insulated wire connections from the blower motor and in their place hook up the two female connectors from the cord Next attach the two male connectors from the cord to the insulated wire ends that were removed from the blower Plug the green wire from the power cord into the short green wire that y...

Page 16: ...B365 Canada or NFPA 211 USA Contact your local building authority prior to attempting any clearance reduction From the front of the insert the clearance to combustible materials such as furniture curtains or fuel is 48 inches 1215 mm in the U S and 60 inches 1525 mm in Canada The clearance from the top of the insert to a 12 inch 305mm mantel is 30 inches 762 mm and to facing trim 1 5 inches 38 mm ...

Page 17: ...late Tile Liner Masonry Positive Connect Installation This method is recommended especially if the existing liner is damaged beyond repair or for chimneys that have historically had low draft or smoke spillage problems This stainless steel liner listed to UL 1777 can be rigid or flexible with a chimney cap and top sealing plate or flashing installed Do not mix and match chimney components Use only...

Page 18: ... The bend on the front of the flue bracket and the hooks on the rear will secure the flue collar tightly to the insert When the flue is in its proper position install the two bolts down through the bracket to secure it Handle Installation The door latch handle and the damper handle are left off for shipping and will need to be installed Both handles and their bolts are packaged in the hardware bag...

Page 19: ... Insert 1 70 300100 1 black Ending manufacturing date june 2011 1 70 300100 2 Charcoal 1 70 300100 3 goldenfire 300i 1 2 3 4 5 6 7 8 9 10 12 23 27 22 14 17 16 18 19 21 24 26 25 20 13 11 15 beginning manufacturing date Sept 2010 Ending manufacturing date Active ...

Page 20: ...LD PSA Gasket 10 Ft 1 00 00999 Y 7 Linkage Kit 1 00 300101 Y 8 Damper Arm Cover 2 00 300121P 9 Left Rear Side 2 00 300104B 10 Left Blower Bracket 2 00 300106 1B Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 11 Blower Left Side 3 21 55416 Y 12 Left Side Shield 2 00 300123P Y Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 13 Load Door Latch Assembly 1 00 06903 Includes Screws Steel Sleeve B...

Page 21: ...2 1 00 249153 Y 21 2 Left Plate Assembly w Gasket 1 10 249117A Y Gasket 1 4 Round White Rope 10 Ft 1 00 11862 Y 21 3 Side Brick Brackets 2 Sets 1 00 06945 Y 21 4 Brick Insulation Qty 2 req 3 40 06944 Y 21 5 Brick 12 x 6 x1 4 Qty 4 req 3 40 86125 Y 21 6 Left Side Brick 3 40 00103 Y 21 7 Logo Brick 3 40 00101 Y 21 8 Brick 9 x 4 1 2 x1 1 4 Set of 7 1 00 900450125 Y 21 9 Shoe Brick Gasket 3 44 06951 Y...

Page 22: ...ay be ordered from an authorized dealer Stocked at depot ITEm dESCrIPTION COmmENTS PArT NumbEr 22 Right Side Shield 2 00 300124P Y Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 23 Power Cord w VSC 3 20 300140 Y 24 Right Blower Bracket 2 00 300106 2B Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 25 Right Rear Side 2 00 300105B 26 Blower Right Side 3 21 32080 Y 27 Combustion Package 3 40 0...

Page 23: ...f new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and ...

Page 24: ...anges in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abrasi...

Page 25: ...ce This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA ...

Reviews: