Summary of Contents for TLC 2000 Stove

Page 1: ...N TLC 2000 STOVE IS NOT PROPERLY INSTALLED A HOUSEFIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACTLOCAL BUILDING OR FIREOFFICIALS ABOUTRESTRICTIONSAND INSTALLA TION INSPECTION REQUIREMENTS INYOUR AREA OPERATOR S MANUAL HARMAN TLC 2000 R6 ...

Page 2: ...rts List 19 Parts Diagram 20 Warranty 21 Please read this entire manual before you install and use your new room heater Failure to follow instructions may result in property damage bodily injury or even death NOT TESTED FOR MOBILE HOME INSTALLATIONS SAVETHESE INSTRUCTIONS Harman Stove Company 352 Mountain House Road Halifax PA 17032 ...

Page 3: ...ier than air This causes accumula tion to occur at the floor first Therefore it is best to install the detector at table top level or lower rather than on the ceiling like a smoke detector CO detectors are very sensitive and may sound an alarm for fumes other than CO or CO from sources other than the stove such as car or lawn mower exhaust If the alarm sounds 1 Increase ventilation by opening wind...

Page 4: ...TLC 2000 Coal Stove 4 Specifications Harman TLC 2000 Weight 375 lbs Flue Size 6 inch Log Length Recommended 16 with 18 Max Heating Capacity 1 900 sq ft Blower Size optional 135 variable speed ...

Page 5: ...Coal Stove 5 Top Load Door Top Load Door Arm Side Shield Ash Door Latch Ash Door Coal Air Control Front Load Door Latch TopLoad Opening Glass Door Grates Wood Air Control Removable Shaker Handle Clean out Cover ...

Page 6: ...triking the glass with a heavy object If the glass is broken or dam aged do not operate the stove until it has been replaced See instructions in the Maintenance section Grates The Harman TLC 2000 s unique grate system consists of two Cast iron grates linked together to operate simaltainiously when the external shaker handleis moved The purpose of the grate system is to to support the coal bed whil...

Page 7: ...lass to form an air curtain works best and keeps the glass clean This is why it is recommended that the coal control be positioned to the left for wood burning WOOD COAL WOOD Building and Maintaining a Wood Fire Never use gasoline gasoline type lantern fuel kerosene charcoallighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater...

Page 8: ...l the ash pan out by the handle Lift the handle to the vertical position to carry the ashes to a disposal location Close the ash door while you are disposing of the ashes The fire will get very hot if the bottom door is left open even for a short period Replace the ash pan Re move ashes from thefire chamber periodically by shaking the grates Wood burns best with an ash bed under the wood therefore...

Page 9: ... smell this is just the paintgoing through the curing process and will disap pear after a few fires Overfiring Avoid overfiring your stove a potentially hazardous situation which can lead to overheating of combustible mate rials damage to the stove and in extreme cases cause a fire Overfiring is caused by 1 Too much air flowing through the stovetoo quickly 2 You may have positioned the primary air...

Page 10: ...aximum postion by sliding it to the right Allow the fire to burn vigorously for several minutes Shake the grates with short choppy strokes until the first red coals fall into the ash pan then stop Add coal to the top of the coal bed It is good to let an edge of red coal exposed to help ignite the gases comming off of the coal These gasses will produce a blue flame The coal air control may be retur...

Page 11: ...tove s glass is cracked or broken you must replace it before operating your stove Remove pieces carefully Replace glass only with Harman Stove Company replacement glass panels do not use substi tutes To replace the glass panel s you will need to remove thedoor To do this open the door lift it straight up and place it on a soft surface Carefully remove damaged glass gasket material and hold down cl...

Page 12: ...el do not over lap the ends Seat the gasket firmly by applying pressure when possible for example after changing the door gasket close the door Allow the cement to dry before using your stove Gaskets are located On the doors to provide airtight closure On the lid Handle The handle on the front door of your TLC 2000 is attached to threaded shafts After a period of time you may find that the front d...

Page 13: ...o a grounded outlet and may not be routed above under over or around the stove itself BlowerVariable Speed knob Top Air Grill Optional The top air grill must be installed before the chimney connector is installed To install simply place the top air grill over the flue out let and position as shown at left It is held in place by gravity The top air grill is a decorative option that does not add or ...

Page 14: ...o combustible materials such as furniture curtains fuel etc is 48 in the U S and 60 in Canada Floor Protection In all installations the area under and around the stove must be protected from falling ash and live coals The floor protector must be of noncombustible material and positioned as shown in the accompanying illustration The guidelines for floor protection are 1 completely under the stove a...

Page 15: ... your stove Signsof an overdraft include rapid fuelconsumption inability to slow the fire and parts of the stove or chimney connector glowing red Itis important that you follow thechimney guide lines in this manual including size type and height to avoid draft problems When installed and operated according to this manual the TLC 2000 will produce enough hot gases to keep the chim ney warm so that ...

Page 16: ...e TLC 2000 must be installed into a chimney ap proved for use with solid fuel appliances In the U S the TLC 2000 must be connected to 1 a prefabricated chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliances UL 103 or 2 a code ap proved masonry chimney with a flue liner In Canada the TLC 2000is listed ...

Page 17: ...n of not venting more than one appliance to the same flue applies to the U S specifi cally While it is not recommended that you use the same chimney for more than one appliance in Canada certain exceptions may be made Be sure to contact your build ing code inspection official to see if this option is allowed in your area and to find out the specific requirements for such an installation ExistingMa...

Page 18: ...rcoal which can cause increased carbon monoxide production or overfiring Never use highly volatile sub stances in your stove such as gasoline which could cause an explosion When solid fuels are burned completely they pro duce water and carbon dioxide However in long slow burns a substantial amount of carbon monoxide may be produced If allowed to build up carbon monoxide which is odorless can prove...

Page 19: ... Door Assembly 15 2 00 852132 TLC Bottom Slide Rail 16A 2 00 852135 TLC Airslide 16B 3 31 08739 5 16 18 x 2 1 2 All Thread 17 2 00 852133 TLC Top Slide Tail 18 2 00 854148 TLC Airslide Cover 19 3 40 08746 TLC Airslide Knob 20 2 00 852136 TLC Ash Door Latch 21 2 00 08725 TLC Long Brick Support 2 per unit 22 2 00 08726 TLC Side Brick Support 2 per unit 23 3 40 900450125 9 x 4 1 2 x 1 1 4 Firebrick 1...

Page 20: ...TLC 2000 Coal Stove 20 26 28 1 22 21 29 9 14 18 12 13 10B 27 3 2 2 4 5 6 32 31 7 8A 11A 23 17 16A 20 15 19 25 24 30 8B 33 10A 11B 16B 34 Brick Backers 2 35 1 4 1 8 Dowel Pins 2 ...

Page 21: ...IONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also ex...